ID Dx.
Name
Description
07 | 01 | 00109
(117506157)
Negative software limit position
Negative software limit position reached
07 | 01 | 00110
(117506158)
Positive software limit position
Positive software limit position reached
07 | 01 | 00111
(117506159)
Limitation negative direction
Limitation of direction of movement owing to
negative software limit position
07 | 01 | 00112
(117506160)
Limitation positive direction
Limitation of direction of movement owing to
positive software limit position
07 | 01 | 00113
(117506161)
Parameterisation of software limit
positions
Parameterisation of software limit positions
invalid
Tab. 308 Diagnostic messages - Software limit position reached
5.6.1
CiA 402
Objects - Software limit position reached
Parameters
Index.Subindex
Name
Data type
Px.
CiA402: factor group is effective.
4629
0x607D.01
Negative software limit position
SINT32
4630
0x607D.02
Positive software limit position
SINT32
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
4628
0x2166.1D
Software limit positions active
BOOL
4629
0x2166.1E
Negative software limit position
SINT64
4630
0x2166.1F
Positive software limit position
SINT64
4631
0x2166.20
Activation of automatic stop ramp software
limit position
BOOL
Tab. 309 Objects
5.7
Standstill monitoring
Standstill monitor STx
The monitoring function indicates that the drive is not moving or that the drive is only moving minim-
ally at a speed that is the lower than the parameterised threshold value. Despite a standstill message
being set, the drive can still move at a threshold value that is not equal to 0. Any drifting is prevented
by additional position monitors.