ID Px.
Parameters
Description
Flag that indicates that modulo limits have been reached. The
signal duration amounts to 1 ms.
Access
read/−
Update
effective immediately
112729
Status modulo limit
reached
Unit
−
Specifies which cam switch is active.
Access
read/−
Update
effective immediately
112730
Status active cam
switch
Unit
−
Specifies how often the modulo limits have been not exceeded.
Access
read/−
Update
effective immediately
112731
Counter NO modulo
cycles
Unit
−
Offset of the modulo position
Access
read/write
Update
effective immediately
112732
Offset modulo posi-
tion
Unit
user defined
Default value for the reference position
Access
read/write
Update
effective immediately
112733
Initialisation of mod-
ulo
Unit
user defined
Specifies the currently used offset of the modulo position.
Access
read/−
Update
effective immediately
112734
Current offset modulo
position
Unit
user defined
Counter for the modulo cycles
Access
read/−
Update
effective immediately
112735
Counter modulo
cycles
Unit
−
Technology functions
405
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW