![Festo CMMT-ST-SW Original Instructions Manual Download Page 576](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377576.webp)
Index.
Subindex
Name
Data type
Access
PDO map-
ping
Parameter
0x2166.07
Monitoring window speed
standstill monitoring
FLOAT32
rw
Rx
P1.466.0.0
0x2166.08
Monitoring window posi-
tion standstill
FLOAT32
rw
Rx
P1.467.0.0
0x2166.09
Damping time target
reached
FLOAT32
rw
Rx
P1.468.0.0
0x2166.0A
Monitoring window target
position
FLOAT32
rw
Rx
P1.469.0.0
0x2166.0B
Monitoring window target
speed
FLOAT32
rw
Rx
P1.4610.0.0
0x2166.0C
Monitoring window target
torque
FLOAT32
rw
Rx
P1.4611.0.0
0x2166.0D
Diagnostic category
UINT16
rw
Rx
P1.4612.0.0
0x2166.0E
Storage option in error log
UINT8
rw
Rx
P1.4613.0.0
0x2166.0F
Diagnostic category
UINT16
rw
Rx
P1.4614.0.0
0x2166.10
Storage option in error log
UINT8
rw
Rx
P1.4615.0.0
0x2166.11
Diagnostic category
UINT16
rw
Rx
P1.4616.0.0
0x2166.12
Storage option in error log
UINT8
rw
Rx
P1.4617.0.0
0x2166.13
Diagnostic category
UINT16
rw
Rx
P1.4618.0.0
0x2166.14
Storage option in error log
UINT8
rw
Rx
P1.4619.0.0
0x2166.15
Diagnostic category
UINT16
rw
Rx
P1.4620.0.0
0x2166.16
Storage option in error log
UINT8
rw
Rx
P1.4621.0.0
0x2166.17
Diagnostic category
UINT16
rw
Rx
P1.4622.0.0
0x2166.18
Storage option in error log
UINT8
rw
Rx
P1.4623.0.0
0x2166.19
Diagnostic category
UINT16
rw
Rx
P1.4624.0.0
0x2166.1A
Storage option in error log
UINT8
rw
Rx
P1.4625.0.0
0x2166.1B
Stop detection limit value
FLOAT32
rw
Rx
P1.4626.0.0
0x2166.1C
Damping time limit detec-
tion
FLOAT32
rw
Rx
P1.4627.0.0
0x2166.1D
Software limit positions
active
BOOL
rw
Rx
P1.4628.0.0
0x2166.1E
Negative software limit
position
SINT64
rw
Rx
P1.4629.0.0
EtherCAT
576
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW