ID Dx.
Message
Description
11 | 05 | 00191
(184877247)
Safety calibration
data incorrect
memory
Can be parameterised: No
Device data incorrect
Remedy
–
Conduct a firmware update
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 05 | 00192
(184877248)
Device data incorrect
Error
memory
Can be parameterised: No
Device data incorrect: Control unit
Remedy
–
Service required
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 05 | 00193
(184877249)
Device data incorrect:
Control unit
Error
memory
Can be parameterised: No
Device data incorrect: Communication unit
Remedy
–
Service required
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 05 | 00194
(184877250)
Device data incorrect:
Communication unit
Error
memory
Can be parameterised: No
Device data incorrect: Safety
Remedy
–
Service required
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 05 | 00195
(184877251)
Device data incorrect:
Safety
Error
memory
Can be parameterised: No
Calibration data incorrect: Control unit
Remedy
–
Service required
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 05 | 00196
(184877252)
Calibration data incor-
rect: Control unit
Error
memory
Can be parameterised: No
Diagnostics and fault clearance
488
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW