ID Px.
Parameters
Description
113007
Current touch probe
mode
Unit
−
Specifies the current sources of the measured values.
This means:
–
0: primary encoder (commutation encoder)
–
1: secondary encoder
–
2: ... (depending on the product design)
Access
read/−
Update
effective immediately
113008
Current touch probe
source
Unit
−
Specifies the currently defined signal edge of the trigger event.
This means:
–
0: inactive
–
1: positive edge
–
2: negative edge 3: positive or negative edge
Access
read/−
Update
effective immediately
113009
Current selection trig-
ger event
Unit
−
Specifies the currently determined upper limit value for the
modulo calculation.
Access
read/−
Update
effective immediately
113010
Current upper limit
value modulo
Unit
user defined
Specifies the currently determined lower limit value for the mod-
ulo calculation.
Access
read/−
Update
effective immediately
113011
Current lower limit
value modulo
Unit
user defined
Specifies the lower limit for trigger signals within the modulo
range. Trigger signals at positions below the limit are ignored.
Access
read/−
Update
effective immediately
113012
Current lower limit
value trigger event
Unit
user defined
Technology functions