ID Px.
Parameters
Description
Specifies the data instance ID of the trigger signal.
Access
read/write
Update
effective immediately
6002
Data instance ID data
trigger
Unit
−
Specifies the array ID of the trigger signal.
Access
read/write
Update
effective immediately
6003
Array ID data trigger
Unit
−
Specifies the trigger event.
The following is possible:
–
0 = Falling edge (signal changes from 1 to 0); for numerical
trigger signals exceeding the threshold in a negative direc-
tion will initiate the trigger.
–
1 = Rising edge (signal changes from 0 to 1); for numerical
trigger signals exceeding the threshold in a positive direc-
tion will initiate the trigger.
–
2 = Any edge (any signal change); for numerical trigger sig-
nals exceeding the threshold in any direction will initiate the
trigger.
–
3 = Value change (any signal change or value change)
–
4 = Comparison (value is the same)
Access
read/write
Update
effective immediately
6004
Trigger event
Unit
−
Specifies the trigger level value. The value is applied as the act-
ive trigger level at the start of the recording (60013). For numer-
ical trigger signals the function depends on the threshold value
of the trigger signal and for digital trigger signals on the digital
signal
Access
read/write
Update
effective immediately
60012
Trigger level
Unit
−
Diagnostics and fault clearance
503
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW