Name
Parameters
ID Px.
M_refM_ref
Setpoint value torque
2220
v_kp
Velocity controller amplification gain
224
v_ki
Velocity controller integration constant
225
v_act
Actual velocity value
1210
v_diff
Velocity control error
2215
v_ref
Setpoint value velocity controller
2216
–LIM1
Minimum torque
2218
+LIM1
Maximum torque
2219
LIM2
Maximum torque symmetrical)
526796
Tab. 349 Legend for the block diagram of the velocity controller
Recommendation: Before changing controller parameters, check the signal of the encoder. If required,
optimise signal noises using a suitable filter time constant.
Parameters and diagnostic messages
ID Px.
Parameters
Description
Specifies the amplification gain for the PI-element in the velocity
controller.
Access
read/write
Update
effective immediately
224
Velocity controller
amplification gain
Unit
−
Specifies the integration constant for the PI-element in the velo-
city controller.
Access
read/write
Update
effective immediately
225
Velocity controller
integration constant
Unit
−
Specifies the velocity measured by the primary encoder.
Access
read/−
Update
effective immediately
1210
Actual velocity value
Unit
user defined
Control
347
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......