–
Metric [m, m/s, …]
–
Imperial [in, in/s, …]
Defining user units
The user units are specified on one of the following pages during axis configuration:
–
è
2.2.3 Initial commissioning assistant
–
è
If there is a change to the user unit with the plug-in, a query appears asking whether the values of the
affected parameters should be reset to the standard values.
If the answer is "no", the values of the affected parameters are recalculated in the new unit taking
into account the feed constant. If the answer is "yes", the values of the affected parameters are reset
to the standard values stored in the firmware.
2.1.6
Automatic data synchronisation
If the plug-in is connected to a device, the plug-in automatically ensures that the data remains syn-
chronised.
Entries by the user are immediately transferred to the device when exiting the input field or when the
[Enter] button is actuated.
A synchronisation is therefore required when a connection to the device is established
è
Synchronising the configuration and parameters.
2.2
Working with CMMT-ST the plug-in
2.2.1
Open plug-in
An overlay dialogue is automatically displayed the first time a plug-in is opened. The following options
are available:
–
"Start first setup..." to open the initial commissioning assistant, which guides the user through
the most important steps in parameterisation.
–
"Manual setup..." for customised input of parameters, starting with the parameter panel for drive
configuration.
If an option is selected, an overlay dialogue is not displayed next time the plug-in is opened.
2.2.2
Connecting the plug-in to the device
2.2.2.1
Connection control
The connection control elements are the same in every context and every plug-in.
CMMT-ST Plug-in
23
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......