ID Px.
Parameters
Description
Update
effective immediately
5517
Basic sampling inter-
val
Unit
−
Tab. 432 Parameters
Example
The recording should be started via a data trigger. The recording should start 0.5 s before the trigger
signal (pre-trigger). Only every second measured value should be recorded in the trace memory.
Parameter settings (example)
Parameters
Value
Comment
Selection of the trigger type
P0.341.0.0
1
Data trigger
Selection of recording delay in the samples
P0.557.0.0
5000
Number of samples before the trigger (5000 * 0.0001 s =
0.5 s)
Selection of down sampling factor
P0.559.0.0
2
Sampling interval should be 100 µs (2 * base time per
sample)
Tab. 433 Parameter settings (example)
Parameters for configuring the trigger event for data triggers
ID Px.
Parameters
Description
Specifies the axis ID of the trigger signal.
0 = System
1 = axis 1
…
n = axis n
Access
read/write
Update
effective immediately
6000
Axis ID data trigger
Unit
−
Specifies the data ID of the trigger signal.
Access
read/write
Update
effective immediately
6001
Data ID data trigger
Unit
−
Diagnostics and fault clearance