background image

GE Industrial Systems

GE Industrial Systems

INSTRUCTIONS

8 Digital Inputs

4 Relay Outputs

D8R4 expanded I/O

for AV-300i Drives

Summary of Contents for D8R4

Page 1: ...GE Industrial Systems GE Industrial Systems INSTRUCTIONS 8 Digital Inputs 4 Relay Outputs D8R4 expanded I O for AV 300i Drives ...

Page 2: ...should be referred to GE Industrial Systems Salem Virginia USA This document contains proprietary information of General Electric Company USA and is furnished to its customer solely to assist that customer in the installation testing operation and or maintenance of the equipment described This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third par...

Page 3: ... the damages which could be caused by the non observance of such indications depends on the different conditions Anyway the instructions given below should always be followed with the highest attention Attire l attention sur les modes d utilization et les procédés et conditions d exploitation qui en cas d inobservation pourraient entraîner la détérioration ou la destruction des appareils La gravit...

Page 4: ... I O Expansion card 4 GEI 100425A ...

Page 5: ...apter 1 INTRODUCTION 12 Chapter 2 MOUNTING 13 Chapter 3 TERMINAL BOARD POINTS 14 3 1 DIGITAL INPUTS TERMINAL BOARD POINTS 14 3 2 RELAY OUTPUTS TERMINAL BOARD POINTS 14 3 3 FUNCTIONAL OVERVIEW 15 Chapter 4 TECHNICAL DATA 17 Dimensions and Weight 17 General Data 18 Digital Inputs 18 Relay Outputs 18 Temperature 18 Chapter 5 ACCESSORIES 19 Chapter 6 MAXIMUM WIRE SIZES 19 ...

Page 6: ...CInputpowersupplyisswitched on Minimumtimetowaitbeforeworkingontheterminalsorinternaldevices is listed in section 5 11 on Hardware Quick Start Up Guide If the front plate has to be removed because the ambient temperature is higher than 40 degrees the user has to ensure that no occasional contact with live parts will occur Always connect the Drive to the protective ground PE via the marked connecti...

Page 7: ...erre est supérieur à 3 5 mA Selon EN 50178 il faut prévoir dans ces cas une double connexion à terre WARNING ELECTRICAL SHOCK AND BURN HAZARD ATTENTION DÉCHARGE ÉLECTRIQUE ET RISQUE DE BRÚLURE When using instruments such as oscilloscopes to work on live equipment the oscilloscope s chassis should be grounded and a differential amplifier input should be used Care should be used in the selection of ...

Page 8: ... use in industrial installations Parts of the Drives are at high voltage during operation The electrical installation and the opening of the device should therefore only be carried out by qualified personnel Improper installation of motors or Drives may therefore cause the failure of the device as well as serious injury to persons or material damage Follow the instructions given in this manual and...

Page 9: ... exceeds the allowable tempe rature Leave the ventilation cover attached for temperatures of 104 F 40 C or below If the Drive s Fault Alarm is activated consult the TROUBLESHOOTING section of Hardware Quick Start Up Guide and after correcting the problem resume operation Do not reset the alarm automatically by external sequence etc Be sure to remove the desicant dryer packet s when unpacking the D...

Page 10: ...code Le raccordement devrait être fait par un connecteur certifié et mentionné à boucle fermé par les normes CSA et UL et dimensionné pour l épaisseur du cable correspondant Le connecteur doit être fixé a l aide d un instrument de serrage specifié par le producteur du connecteur Ne pas exécuter un test megger entre les bornes du drive ou entre les bornes du circuit de contrôle Étant donné que la t...

Page 11: ...sts de rigidité diélectrique sur des parties du convertisseurs Pour mesurer les tensions des signaux il faut utiliser des instruments de mesure appropriés résistance interne minimale 10 kΩ V NOTE If the Drives have been stored for longer than three years the operation of the DC link capacitors may be impaired Before commissioning devices that have been stored for long periods connect them to a pow...

Page 12: ...adds digital Inputs and relay outputs to the drive It is possible to use only one I O expansion card per Drive This option card features 8 optocoupled digital inputs 15V up to 30VDC 4 relay outputs with 250V max dry contact 1 N O 1N C contact per relay Front side Back side ...

Page 13: ...n and expansion card 1 Switch the drive off 2 Fasten the D8R4 card to the drive regulation board by means of screws B and standoffs A 3 The D8R4 card is connected to the regulator card through the XH connector using the supplied cable The power supply 5V and the control signals are provided by the drive via the XH connector 4 Switch on the drive ...

Page 14: ... GND Function Fw 2 X DI4X DI5X DI6X DI7X GND n a not available expD10 XDI0 XDI1 DIGITAL INPUTS 3 2 RELAY OUTPUTS TERMINAL BOARD POINTS Relay outputs need a 24V 60mA supply voltage The Drive TB can be used to supply 24VDC power AV 300i 24VDC supply maximum output 120 mA total including Encoder LAN Expansion card and DGF or350mAwithoutDGF Connector Relay Terminal 114 111 112 214 211 212 Function N O...

Page 15: ... Digital input 5 DI0X Digital input 6 DI1X 7 Digital input DI2X Digital input 8 DI3X GND 36 37 38 39 DIGITAL INPUTS CONNECTOR XDI1 40 DI4X DI5X DI6X DI7X GND 112 114 101 100 111 212 214 211 312 314 311 412 414 411 RELAY OUTPUTS CONNECTOR XCQ00 N Closed N Open COM N Closed N Open COM N Closed N Open COM N Closed N Open COM RELAY OUTPUTS CONNECTOR XCQ01 24V 0V COM POWER SUPPLY CONNECTOR XSC NOTE in ...

Page 16: ...ting Drive firmware setting 31 Digital input 5 DI0X 32 Digital input 6 DI1X 33 Digital input 7 DI2X 34 Digital input 8 DI3X 36 not available DI4X 37 not available DI5X 38 not available DI6X 39 not available DI7X 111 112 114 Digital output 3 DO0X 211 212 214 Digital output 4 DO1X 311 312 314 Digital output 5 DO2X 411 412 414 Digital output 6 DO3X exp50 Digital Inputs Relay Outputs setting ...

Page 17: ...d D8R4 expanded I O Chapter 4 TECHNICAL DATA DimensionsandWeight 92 mm 3 6 118 mm 4 6 Dimensions ________________________________ 118 mm 4 6 inches x 92 mm 3 6 inches Weight _____________________________________ 113 g 4 oz ...

Page 18: ...____ 4 Max contact Voltage Current value ______________ 250V max 5A max 250VAC 4 A ohmic load 1 2A inductive load cosphi 0 4 up to 0 7 115VAC 5 A ohmic load 2 6A inductive load cosphi 0 4 up to 0 7 24VDC 400mA Min contact Voltage Current value ______________ 20V 50mA Relay driving type ___________________________ open emitter optocoupled Relay power supply external __________________ 24V 20 50 20 ...

Page 19: ...LAND 6 contacts 25 340 3653 0 Terminals XDI0 XDI1 _____________________ Type PHOENIX CONTACT 5 contacts MC1 5 5 ST3 81 1803604 or equivalent Terminals XSC ___________________________ Type PHOENIX CONTACT 2 contacts MC1 5 2 ST3 81 1803578 or equivalent Chapter 6 MAXIMUM WIRE SIZES Terminals on connector mm2 AWG XSC XDI0 XDI1 0 14 1 5 28 16 XCQ0 XCQ1 0 2 2 5 24 12 exp40 ...

Page 20: ...1S5G17 GEI 100425A 001109 SIEI GE Industrial Systems 1 540 387 7000 www GEindustrial com General Electric Company 1501 Roanoke Blvd Salem VA 24153 6492 USA ...

Reviews: