Situation
Reaction
Axis zero-point was not reached
Homing aborted with fault message.
Limit switch detected
Homing aborted with fault message.
Stop detected
Homing aborted with fault message.
Tab. 254 Different sequence scenarios
4.4.4
CiA 402
Objects for homing
Parameters
Index.Subindex
Name
Data type
Px.
CiA402: factor group is effective.
843
0x6099.01
Search for reference mark setpoint velocity
UINT32
844
0x609A.01
Search for reference mark setpoint accelera-
tion
UINT32
846
0x6099.02
Setpoint reference mark creeping velocity
UINT32
847
0x609A.02
Setpoint reference mark creeping acceleration UINT32
849
0x6099.03
Move to axis zero point setpoint velocity
UINT32
8410
0x609A.03
Move to axis zero point setpoint acceleration
UINT32
8416
0x607C.00
Axis zero point offset
SINT32
8417
0x6098.00
Referencing method
SINT8
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
840
0x2172.01
Referencing status
UINT32
841
0x2172.02
Move to axis zero point after homing
BOOL
842
0x2172.03
Homing timeout
FLOAT32
843
0x2172.04
Search for reference mark setpoint velocity
FLOAT32
844
0x2172.05
Search for reference mark setpoint accelera-
tion
FLOAT32
845
0x2172.06
Search for reference mark setpoint jerk
FLOAT32
846
0x2172.07
Setpoint reference mark creeping velocity
FLOAT32
847
0x2172.08
Setpoint reference mark creeping acceleration FLOAT32
848
0x2172.09
Setpoint reference mark creeping jerk
FLOAT32
849
0x2172.0A
Move to axis zero point setpoint velocity
FLOAT32
8410
0x2172.0B
Move to axis zero point setpoint acceleration
FLOAT32
Motion control
275