ID Px.
Parameters
Description
Determines the upper limit value for the modulo calculation.
When the upper limit value is exceeded, the position jumps to
the lower limit value.
Access
read/write
Update
effective immediately
112702
Upper limit value
modulo
Unit
user defined
Determines the lower limit value for the modulo calculation.
When the lower limit value is undershot, the position jumps to
the upper limit value.
Access
read/write
Update
effective immediately
112703
Lower limit value
modulo
Unit
user defined
Determines the inactive time compensation for the signal
change for the first switching point. With this parameter, switch-
on delays of external components can be compensated.
Access
read/write
Update
effective immediately
112704
Inactive time com-
pensation of first
switching point
Unit
s
Determines the inactive time compensation for the signal
change for the second switching point. With this parameter,
switch-on delays of external components can be compensated.
Access
read/write
Update
effective immediately
112705
Inactive time com-
pensation of second
switching point
Unit
s
Through the determination of the hysteresis range, undesired
switching procedures are suppressed around the switching
point during fluctuations.
Access
read/write
Update
effective immediately
112706
Hysteresis
Unit
user defined
Determines the switching time for time-based manual switching
(mode 4/5).
Access
read/write
112707
Switching time
(manual)
Update
effective immediately
Technology functions
399
Festo — CMMT-ST-SW — 2019-02