![Festo CMMT-ST-SW Original Instructions Manual Download Page 454](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377454.webp)
ID Dx.
Message
Description
The speed specified for the trajectory generator is invalid
Remedy
–
Change specified velocity to valid range
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
05 | 02 | 00073
(84017225)
Invalid speed value of
trajectory generator
Error
memory
Can be parameterised: No
The acceleration specified for the trajectory generator is
invalid
Remedy
–
Change specified acceleration to valid
range
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
05 | 02 | 00074
(84017226)
Invalid acceleration
value of trajectory
generator
Error
memory
Can be parameterised: No
The deceleration specified for the trajectory generator is
invalid
Remedy
–
Change specified deceleration to valid
range
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
05 | 02 | 00075
(84017227)
Invalid deceleration
value of trajectory
generator
Error
memory
Can be parameterised: No
The jerk specified for the trajectory generator is invalid
Remedy
–
Change specified jerk to valid range
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
05 | 02 | 00076
(84017228)
Invalid jerk value of
trajectory generator
Error
memory
Can be parameterised: No
An error occurred in the trajectory generator when calcu-
lating a movement profile
Remedy
–
Adjust dynamic values for the motion task
Default: Stop category 1 (256)
05 | 02 | 00077
(84017229)
Trajectory generator
error
Classifica-
tion
Can be parameterised: No
Diagnostics and fault clearance
454
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......