ID Px.
Parameters
Description
Displays the scaling factor for the maximum value based on the
limit value, after drive is at standstill.
Access
read/−
Update
effective immediately
6315
Scaling factor maxim-
um value after drive
at standstill
Unit
−
Specifies the actual value for I²t monitoring of the power output
stage at standstill.
Access
read/−
Update
effective immediately
6316
Actual value I²t monit-
oring power output
stage at standstill
Unit
A²s
Specifies the scaling factor for the warning limit based on the
limit value of the I²t monitoring of the power output stage if the
drive is at standstill.
Access
read/write
Update
effective immediately
6317
Scaling factor warning
limit I²t monitoring
drive at standstill
Unit
−
Specifies the actual value for relative I²t monitoring of the power
output stage to the limit.
Access
read/−
Update
effective immediately
6332
Actual value relative
I²t monitoring of
power output stage to
limit
Unit
−
Specifies the actual value for relative I²t monitoring of the power
output stage at standstill to the limit.
Access
read/−
Update
effective immediately
6333
Actual value relative
I²t monitoring of
power output stage at
standstill to limit
Unit
−
Specifies the current actual value of the I²t monitoring of the
total current.
Access
read/−
Update
effective immediately
6334
Actual value I²t monit-
oring of the total cur-
rent
Unit
Arms
Tab. 157 Parameters of “I²t monitoring of power output stage”
Product configuration
186
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......