ID Dx.
Message
Description
Target torque reached
Remedy
–
none (info only)
Default: Info (4)
Classifica-
tion
Can be parameterised: Px.4616, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: do not save (0)
07 | 02 | 00123
(117571707)
Target torque reached
Error
memory
Can be parameterised: Px.4617
Standstill reached
Remedy
–
none (info only)
Default: Info (4)
Classifica-
tion
Can be parameterised: Px.4618, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: do not save (0)
07 | 02 | 00124
(117571708)
Standstill reached
Error
memory
Can be parameterised: Px.4619
Standstill reached and within standstill window
Remedy
–
none (info only)
Default: Info (4)
Classifica-
tion
Can be parameterised: Px.4620, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: do not save (0)
07 | 02 | 00125
(117571709)
Standstill reached
and within standstill
window
Error
memory
Can be parameterised: Px.4621