Index.
Subindex
Name
Data type
Access
PDO map-
ping
Parameter
0x2166.40
Diagnostic category
UINT16
rw
Rx
P1.4678.0.0
0x2166.41
Storage option in error log
UINT8
rw
Rx
P1.4679.0.0
0x2166.42
Current position: following
error
FLOAT32
ro
Tx
P1.4682.0.0
0x2166.43
Current velocity: following
error
FLOAT32
ro
Tx
P1.4683.0.0
0x2166.44
Actual stroke value
SINT64
ro
Tx
P1.4684.0.0
0x2166.45
Limit value remaining dis-
tance monitoring
SINT64
rw
Rx
P1.4685.0.0
0x2166.46
Diagnostic category
UINT16
rw
Rx
P1.4686.0.0
0x2166.47
Storage option in error log
UINT8
rw
Rx
P1.4687.0.0
0x2166.48
Bit mask movement monit-
oring
UINT32
rw
Rx
P1.4688.0.0
0x2166.49
Movement monitoring
(masked)
UINT32
ro
Tx
P1.4689.0.0
0x2166.4A
Damping time velocity: fol-
lowing error
FLOAT32
rw
Rx
P1.4690.0.0
0x2166.4B
Diagnostic category
UINT16
rw
Rx
P1.4691.0.0
0x2166.4C
Storage option in error log
UINT8
rw
Rx
P1.4692.0.0
0x2166.4D
Diagnostic category
UINT16
rw
Rx
P1.4647.0.0
0x2166.4E
Storage option in error log
UINT8
rw
Rx
P1.4648.0.0
0x2166.4F
Diagnostic category
UINT16
rw
Rx
P1.4649.0.0
0x2166.50
Storage option in error log
UINT8
rw
Rx
P1.4650.0.0
0x2166.51
Fixed stop detection damp-
ing time
FLOAT32
rw
Rx
P1.4693.0.0
0x2166.52
Limit value following error
FLOAT32
rw
Rx
P1.4694.0.0
0x2166.53
Stroke limit positive for
detection of a fixed stop
SINT64
rw
Rx
P1.11280408.0.0
0x2166.54
Stroke limit negative for
detection of a fixed stop
SINT64
rw
Rx
P1.11280409.0.0
0x2166.55
Threshold value torque
utilization reached
FLOAT32
rw
Rx
P1.11280410.0.0
0x2167.01
Device control status
UINT32
ro
Tx
P1.530.0.0
EtherCAT
578
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......