ID Px.
Parameters
Description
Index 2: (depending on the product design)
Index 3: …
Access
read/write
Update
effective immediately
112710
First switching point
Unit
user defined
Defines the second switching point at which the cam switch
should be active.
Index 0: cam switch 1
Index 1: cam switch 2
Index 2: (depending on the product design)
Index 3: …
Access
read/write
Update
effective immediately
112711
Second switching
point
Unit
user defined
Duration for which the cam is active.
Index 0: cam switch 1
Index 1: cam switch 2
Index 2: (depending on the product design)
Index 3: …
Access
read/write
Update
effective immediately
112712
Switching time (auto-
matic)
Unit
s
Specifies the current mode of the cam controller function.
Access
read/−
Update
effective immediately
112713
Current cam controller
mode
Unit
−
Specifies the current source of the position values of the cam
controller.
This means:
–
0: primary encoder (commutation encoder)
–
1: secondary encoder
–
2: ... (depending on the product design)
Access
read/−
Update
effective immediately
112714
Current cam controller
source
Unit
−
Technology functions
401
Festo — CMMT-ST-SW — 2019-02