background image

 

 

 

 

 

 

Hardware Manual of the Easy Servo Drives 

ES-DH Series 

Summary of Contents for ES-DH Series

Page 1: ...i Hardware Manual of the Easy Servo Drives ES DH Series ...

Page 2: ...ent Caution Make sure the power supply voltage dose not exceed the drive s input range Double check the connections and make sure the power lead polarity is correct Warning Do not set high current for small stepper motor It is possible that the motor will be damaged Caution Disconnect the motor from the load if you are not sure the move direction Adjust the axis in the center before trying to run ...

Page 3: ...11 Display Data Mode 12 Edit Parameter Mode 13 Configuration Example via the on board HMI 15 Calculating Rotation Speed and Angle 16 Rotating the Motor via the On board HMI 16 Rotating the Motor by Motion Controller 17 Rotating the ES Motor in PC Software 17 Power Supply Selection 18 Multiple Drives 18 Selecting Supply Voltage 18 Recommended Supply Voltage 19 Control Signal Setup Timing 19 Current...

Page 4: ...iv Obtaining Warranty Service 23 Warranty Limitations 23 Shipping Failed Product 23 Contact Us 24 ...

Page 5: ...ologies and delivers unique capabilities and enhancements over both while at a fraction of the cost of a servo system Getting Start To get start you need one easy servo drive one easy servo motor stepper drive with encoder and an AC DC power supply for the first time evaluation A motion controller like indexer pulse generator or PLC is required too if you would like to verify the complete function...

Page 6: ...Hardware manual of the ES DH series drives 2 Wiring Diagrams Wiring Diagram of the ES DH1208 and ES MH2 series motor Wiring Diagram of the ES DH2306 and ES MH3 series motor ...

Page 7: ...s of the ES DH1208 ES DH2306 The ES DH2306 requires two powers input as follows The main power is used to energize the motor and the control power is used for logic circuit Typically they can share the same AC power AC Power connections of the ES DH2306 L N PE Power L N PE AC Power 70 130VAC L N PE Main Power L N PE Control Power L N AC Power 150 230VAC ...

Page 8: ...d 4 2 Power Extension Cable Power Cable 3 B B Yellow Green Blue Connect Leadshine ES MH2 series motors to the ES DH1208 ES DH2306 and the ES MH3 Series Motor A power extension cable is required to connect the ES MH3 series motors and the ES DH2306 One end of this power extension cable includes four flying wires You can connect these wires to the drive s corresponding terminals as follows ES DH2306...

Page 9: ... of the ES DH drive is a HDD15 female connector However you can NOT connect them directly as their pin out are not matched to each other An encoder extension cable must be connected between the drive and motor ES DH1208 CN2 Feedback Signal Connector ES MH23480 ES MH234120 Encoder Extension Cable Encoder Cable must be used Encoder connections between ES DH1208 drive and ES MH2 motor ES DH2306 CN2 F...

Page 10: ...drive If you don t need to disable the drive just leave them unconnected In a NPN sourcing type output the control signals share the same positive terminal ES DH Drive PUL DIR PUL DIR ENA ENA 5 24V 5V recommended Step Direction Enable Controller Connect the ES DH drives to the NPN sinking type controllers In a PNP sinking type output the control signals are refer to the same ground terminal ES DH ...

Page 11: ...the differential type controller Alarm Output The outputs is isolated and you can take it as an electronic switch A upper resistor should be used to limit the current Its resistance is depending on the input current requirement of the controller The source voltage for those outputs can also be 24V The resistor R is depending on the input current of the controller ES DH Drive ALM ...

Page 12: ...your PC and make it ready for use later Connect ES DH drive to PC A RS232 cable is needed for the communication between the drives and the ProTuner It will be shipped with the kit if you include it in the order It is also possible to make this cable by yourself One end of this cable is a 6 pin fire wire header and the other end of cable is a 9 pin D Sub female connector If your PC does not have a ...

Page 13: ... Cable 3 B B Yellow Green Blue 5 PE 6 NC Typical Connections of ES DH1208 with controller of sinking output ES DH2306 PUL 3 DIR 5 PUL DIR 4 6 ALM 7 CN1 Control Signal Connector ENA 11 ENA 12 8 ALM 5 24V 5V recommended Step Direction Enable Alarm Controller 5V N L CN2 Feedback Signal Connector Control Power Braking Resistor Connector 5 6 L N NC BR P 1 2 3 4 5 Main Power Motor Connector 150 230VAC E...

Page 14: ... easy servo drives are not suitable for your application it is necessary to configure it via the on board HMI or the configuration software ProTuner Otherwise you may encounter problems like high motor heating big motor noise or even motor stall due to weak torque For a quick start of the easy servo drive there are not much parameters need to be configured The following table gives the most signif...

Page 15: ...ys for users operation as follows M ENT There are 4 operation modes in the on board HMI Users can switch between these modes by pressing the Mode key The following figure illustrates the operation procedure of this on board HMI M Display Data Edit Parameter Select Data ENT Display Data Select Parameter Display parameter Edit Parameter Confirm M Cancel ENT ENT Select Function Hold on 3 seconds Rese...

Page 16: ...e between command and feedback Press to switch between low and high order digits display d01SPF Actual feedback motor speed in RPM d02SPr Reference motor speed in RPM d03PLF Actual feedback position in pulses d04PLr Reference position in pulses d05iP Reference current peak in mA d06Err Error code 0001 Over current protection activated 0002 Over voltage protection activated 0008 Brake protection ac...

Page 17: ...f 30 0 100 Compensate the motor and control loop delay PA__07 Pulses Revolution 4000 200 65535 Set the pulses count to make the motor rotate one revolution PA__08 Encoder Resolution 4000 200 65535 X4 quadrature decoding default value is for 1000 lines encoder PA__09 Position Error Limit 1000 1 65535 When the position error exceeds this value the drive goes into error state Unit Pulses PA__10 Holdi...

Page 18: ..._17 Pulse Mode 0 0 or 1 0 Pulse Direction 1 Pulse Pulse CW CCW PA__18 Pulse Edge 0 0 or 1 0 Active Rising Edge 1 Active Falling Edge PA__19 Motor Direction 1 0 or 1 0 and 1 represents two different directions CW CCW PA__20 Pulse Bandwidth 0 0 or 1 0 The MAX pulse frequency is limited to 200KHz 1 The MAX pulse frequency is limited to 500KHz PA__21 Acceleration 200 1 2000 Acceleration of the built i...

Page 19: ...o into the Edit Parameter Mode Initially it displays the PA__00 and the 1st from right to left digit is blinking Press 2 times to increase the 1st digit It displays PA__02 to indicates the parameter No 2 Press key once ENT It displays the low order digits of the position error at Power up Press the ENT key Power Up the 2nd from right to left digit is blinking Press to decrease the digit in case of...

Page 20: ... distance acceleration and initial direction etc The detailed steps are shown in the following picture Display Data Position Error M Press M key once to go into the Edit Parameter Mode Initially it displays the PA__00 and the 1st from right to left digit is blinking Press 3 times to decrease the number It displays PA__28 to indicates the parameter No 28 ENT It displays the low order digits of the ...

Page 21: ...and current setting The minimum speed is limited by Standby Time see more information in page 13 regarding Standby Timer Rotating the ES Motor in PC Software There is a simple emulating controller that is used for self test in the ES drive It is not a full functionality controller but it does eliminate the troubles to setup a real motion controller when you want to test the ES drives or verify the...

Page 22: ... has enough capacity To avoid cross interference DO NOT daisy chain the power supply input pins of the drives Instead please connect them to power supply separately Selecting Supply Voltage Higher supply voltage can increase motor torque at higher speeds thus helpful for avoiding losing steps However higher voltage may cause bigger motor vibration at lower speed and it may also cause over voltage ...

Page 23: ...p Timing To make a reliable operation the ES drive requires the control signals to meet the setup time requirements as follows Otherwise losing of steps may happen Control Signal Setup Time Drive Frequency tDS tPHS tPLS tDD tES tED ES DH2306 200K 5uS 2 5us 5uS 50ms 50ms ES DH2306 500K 5uS 1 0us 5uS 50ms 50ms ES DH1208 200K 5uS 2 5us 5uS 50ms 50ms ES DH1208 5200K 5uS 1 0us 5uS 50ms 50ms Symbol Desc...

Page 24: ...hether or not there is big vibration at start up and how much lock torque is required based on your actual applications Fine Tuning Leadshine already loads default current loop parameters and position loop parameters Those default parameter values have been optimized They should be good enough for most industrial applications and there is no need to tune them However if you want to fine tune the I...

Page 25: ...r supply voltage exceeds the limits protection will be activated and red LED will blink twice within each periodic time Caution When above protections are active the motor shaft will be free and the LED will blink Reset the drive by repowering it to make it function properly after removing above problems Position Following Error Protection When the position error exceeds its limit software configu...

Page 26: ...termining the problem should you need assistance Many of the problems that affect motion control systems can be traced to electrical noise controller software errors or mistake in wiring Problem Symptoms and Possible Causes Symptoms Possible Problems No power Encoder resolution setting is wrong Fault condition exists Motor is not rotating The drive is disabled Motor rotates in the wrong direction ...

Page 27: ...ts returned to Leadshine for warranty service and Leadshine shall pay for return of products to customer Warranty Limitations Leadshine makes no other warranty either expressed or implied with respect to the product Leadshine specifically disclaims the implied warranties of merchantability and fitness for a particular purpose Some jurisdictions do not allow limitations on how long and implied warr...

Page 28: ...ca areas 86 755 2640 9254 for Europe areas 86 755 2641 7617 for America areas Fax 86 755 2640 2718 Email sales leadshine com Technical Support Tel 86 755 2641 8447 86 755 2641 8774 86 755 2641 0546 Fax 86 755 2640 2718 Email tech leadshine com for All Leadshine U S A Address 25 Mauchly Suite 318 Irvine California 92618 Tel 1 949 608 7270 Fax 1 949 608 7298 Web http www leadshineUSA com Email sales...

Reviews: