Hardware
manual of the ES-DH series drives
15
“
PA__27
”
Motion Type
1
0 or 1
0----One direction motion
1----Positive and negative motion
“
PA__28
”
Motion Start/Stop
0
0 or 1
1----Start Motion
0----Stop Motion
The motion starts when applying
“
1
”
to
this parameter. It backs to
“
0
”
when the
motion completes.
“
PA__29
”
Reserved
-
-
-
Configuration Example via the on-board HMI
The following figure illustrates how to set the
“
Standby Time
”
via the on-board HMI. Looking up the
table in the
“
Edit Parameter Mode
”
section, this parameter refers to
“
PA__12
”
item. So the setting
procedure is shown as follows:
Display Data:
“
Position Error
”
M
Press
“
M
”
key once to go into
the
“
Edit Parameter Mode
”
Initially it displays the
“
PA__00
”
and
the 1st (from right to left) digit is blinking
Press
“
”
2 times to
increase the 1st digit
It displays
“
PA__02
”
to
indicates the parameter No. 2
Press
“
”
key once
ENT
It displays the low order digits of
the position error at Power-up
Press the ENT
”
key
Power-Up
the 2nd (from right to left) digit
is blinking
Press
“
”
to decrease the
digit in case of wrong operation
ENT
Press the ENT
”
key to confirm
the selection of the
“
PA__12
”
It displays the
“
PA__12
”
value of
1000ms which is the Standby Time.
Edit the value by the up-arrow
(increase), the down-arrow (decrease)
and the left-arrow (left shift) keys.
Change the Standby Time to 1294ms.
ENT
Press the ENT
”
key to confirm
the new value.
Press
“
”
1 times to
increase the 2nd digit
It returns to the
“
Edit Parameters Mode
”
M
Press
“
M
”
key