Hardware
manual of the ES-DH series drives
4
Connecting Motor
ES-DH1208 and the ES-MH2 Series Motor
A power extension cable is required to connect the ES-MH2 series motors and the ES-DH1208. One
end of this power extension cable includes four flying wires. You can connect these wires to the
drive
’
s corresponding terminals as follows.
ES-DH1208
Motor Connector
ES-MH23480
ES-MH234120
A+
A-
1
Black
Red
4
2
Power
Extension Cable
Power
Cable
3
B+
B-
Yellow/ Green
Blue
Connect Leadshine ES-MH2 series motors to the ES-DH1208
ES-DH2306 and the ES-MH3 Series Motor
A power extension cable is required to connect the ES-MH3 series motors and the ES-DH2306. One
end of this power extension cable includes four flying wires. You can connect these wires to the
drive
’
s corresponding terminals as follows.
ES-DH2306
Main Power &
Motor Connector
ES-MH33480
ES-MH342120
ES-MH342200
Power
Cable
U
V
1
Black
Red
4
2
Power
Extension Cable
3
W
PE
Yellow/ Green
Blue
Connect Leadshine ES-MH3 series motors to the ES-DH2306