resequence access-list
Re-assign sequence numbers to entries of an existing access-list.
S6000
Syntax
resequence access-list {ipv4 | ipv6 | mac} {
access-list-name StartingSeqNum Step-
to-Increment
}
Parameters
ipv4 | ipv6 |
mac
Enter the keyword
ipv4
or
mac
to identify the access list type
to resequence.
access-list-
name
Enter the name of a configured IP access list.
StartingSeqNu
m
Enter the starting sequence number to resequence. The
range is from 0 to 4294967290.
Step-to-
Increment
Enter the step to increment the sequence number. The
range is from 1 to 4294967290.
Defaults
none
Command
Modes
• EXEC
• EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Introduced on the S6000.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 8.2.1.0
Introduced on the E-Series ExaScale (IPv6).
Version 8.1.1.0
Introduced on the E-Series ExaScale (IPv4).
Version 7.8.1.0
Increased the name string to accept up to 140 characters.
Prior to 7.8.1.0, names were up to 16 characters long.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
Version 7.4.1.0
Introduced on the E-Series.
182
Access Control Lists (ACL)
Содержание Networking S6000 System
Страница 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Страница 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Страница 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Страница 773: ...dropped in keepalive Dell Related Commands show ip cam stack unit displays the CAM table IPv4 Routing 773 ...
Страница 1319: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1319 ...
Страница 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Страница 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...