cam-acl
{default | l2acl
number
ipv4acl
number
ipv6acl
number
,
ipv4qos
number
l2qos
number
l2pt
nu
mber
ipmacacl
number
ecfmacl
number
[vman-
qos | vman-
dual-qos
number
}
Allocate space to each CAM region.
Enter the CAM profile name then the amount of CAM space
to be allotted. The total space allocated must equal 13. The
ipv6acl range must be a factor of 2.
Enter
4
or
8
for the number of OpenFlow FP blocks.
•
4
: Creates 242 entries for use by the OpenFlow controller
(256 total entries minus the 14 entries reserved for
internal functionality)
•
8
: Creates 498 entries for use by the OpenFlow controller
(512 total entries minus the 14 entries reserved for
internal functionality)
Enter the CAM profile name followed by the amount to be
allotted. The total space allocated must equal 13. The ipv6acl
range must be a factor of 2.
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Introduced on the S6000.
Version 9.2(0.2)
Added support for the
fcoe
parameter on the S4810 and
S4820T.
Version 9.1.
(0.0)
Added support for OpenFlow on the Z9000.
Version
8.3.19.0
Introduced on the S4820T.
Version
8.3.12.0
Added the keywords
fcoeacl
and
iscsioptacl
on the
S4810.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.1.0
Added the keywords
ecfmacl
,
vman-qos
, and
vman-dual-
qos
.
Version 8.2.1.0
Introduced on the S-Series.
Version 7.8.1.0
Introduced on the C-Series.
Usage
Information
For the new settings to take effect, save the new CAM settings to the startup-
config (
write-mem
or
copy run start
) then reload the system.
Control and Monitoring
81
Содержание Networking S6000 System
Страница 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Страница 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Страница 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Страница 773: ...dropped in keepalive Dell Related Commands show ip cam stack unit displays the CAM table IPv4 Routing 773 ...
Страница 1319: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1319 ...
Страница 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Страница 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...