Страница 1: ...USER GUIDE www kontron com KSwitch D1 UGP Unmanaged Gigabit PoE Ethernet Switch Doc Preliminary User Guide Rev 0 9 Doc ID 1068 1428...

Страница 2: ...KSwitch D1 UGP Unmanaged Gigabit PoE Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 2 This page has been intentionally left blank...

Страница 3: ...ation or warranty that such application will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general d...

Страница 4: ...isk Applications is entirely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible fo...

Страница 5: ...on contacts by visiting https www kontron com support and services kontron europe and asia support contact support Customer Service As a trusted technology innovator and global solutions provider Kont...

Страница 6: ...ions indicated and or prescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title informs that the electronic boards and the...

Страница 7: ...ation of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations on this product Therefore always unplug the power cable and any other cables wh...

Страница 8: ...ort circuits and damage the batteries or conductive circuits on the product Lithium Battery Precautions If your product is equipped with a lithium battery take the following precautions when replacing...

Страница 9: ...components used are capable of being recycled Final disposal of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations WEEE...

Страница 10: ...ent and Packaging 15 3 1 Packaging 15 3 2 Unpacking 15 3 3 Scope of Delivery 15 3 4 Accessories 16 3 5 Product Identification Type Label 17 4 Features 18 4 1 Faceplate Features 19 4 1 1 RJ45 Copper Et...

Страница 11: ...cification 30 Table 6 Environmental Specification 31 Table 7 Certification Compliance 31 Table 8 Mechanical Specification 31 Table 9 Electrical Specification 33 Table 10 List of Acronyms 38 List of Fi...

Страница 12: ...this user guide visit Kontron s KSwitch Industrial Ethernet Switches at https www kontron com products systems ethernet solutions This user guide provides an overview of the switches features and ava...

Страница 13: ...ted Power Source LPS and Power Source PS2 of UL IEC 62368 1 Only products or parts that meet the requirements for Power Source PS1 of UL IEC 62368 1 may be connected to the product s available interfa...

Страница 14: ...onnector attached to a broken fiber or an energized fiber 2 2 Electrostatic Discharge ESD A sudden discharge of electrostatic electricity can destroy static sensitive devices or micro circuitry Theref...

Страница 15: ...hipping damage or inconsistencies between the contents and the original order contact Kontron for help and information 3 3 Scope of Delivery Check that your delivery is complete and contains the items...

Страница 16: ...witch to be installed in a 2U rack RK4U 19 Rack Mount Kit 4U Enables DIN Rail switch to be installed in a 4U rack WK25 Wall Mount Kit 2x wall mount plates and screws Power Supply Adapter 230 VAC to DC...

Страница 17: ...www kontron com 17 3 5 Product Identification Type Label Figure 1 Type Label 1 Model full name 2 Series name 3 Part Number PN with bar code 4 Revision 5 Serial Number SN with barcode 6 Production date...

Страница 18: ...oE injector series is an unmanaged Gigabit industrial PoE injector that meets the IEEE 802 3af at standard with up to 60 Watts output in a ruggedized design Figure 2 KSwitch D1 UGP PoE Injector DC ver...

Страница 19: ...thernet IEEE 802 3ab compliant for Gigabit Ethernet The PoE port is an IEEE 802 3af at PoE compatible PSE output port When connected to a Powered Device PD the switch automatically detects if the PD i...

Страница 20: ...and in the case of failure may be used for faultfinding Figure 4 Indicator LEDs DC version AC Version Table 3 Indicator LEDs LED Name Indicator Color Condition SYS DC version PWR AC version On Green P...

Страница 21: ...g Figure 5 DC Terminal Block When connecting the power follow the indicated polarity V The external DC power supply must be connected to a well fused power supply When attaching power wires to the DC...

Страница 22: ...nal block as the primary power source With multiple power sources connected to the switch the switch utilizes the power supply with the higher voltage or the most stable power supply 4 2 3 DIP Switch...

Страница 23: ...be grounded properly for optimum system performance Figure 8 Ground Connector DC Version When connecting a ground wire to the switch ensure that the wire size range is 18 to 14 AWG and resistance is...

Страница 24: ...ype IEC 320 100 VAC 240 VAC 50 Hz 60 Hz that connects to a mains power outlet using an AC power cable see Table 2 List of Accessories Figure 9 AC Power Connector 4 3 2 Ground Connector The switch must...

Страница 25: ...orientation of the DIN Rail clip to be changed by 180 Sets of mounting holes at the top and bottom of the rear side enable installation of wall mount plates For mounting information see Chapter 5 Moun...

Страница 26: ...tch Only authorized well trained professionals should be allowed to access the restricted access location Access should be controlled by the authority responsible for the location with a lock and key...

Страница 27: ...nt plate s mounting holes to the top of the wall mount plate is 27 mm To install the wall mount plate supplied in the wall mount kits perform the following 1 Make sure the mounting surface is clean an...

Страница 28: ...in your local national and international region Ensure easy access to the power cable If the operating environment restricts power cable access guarantee disconnection using a separate cut off fixtur...

Страница 29: ...ocket automatically activates the switch Do not use an extension cable to connect the switch 6 3 Connecting to AC Power Connector AC Version To connect the switch to AC main power 100 VAC 240 VAC 50Hz...

Страница 30: ...able by DIP Switch PD Detection Yes PoE enabled device detected before sending power If a non PoE device is detected power will not be soured instead Ethernet communications is permitted In Force mode...

Страница 31: ...ss B EN 61000 6 4 EN 61000 6 2 and EN 55035 Safety UL IEC EN 62368 1 FCC According to requirements of 47 CFR FCC Part 15 Subpart B Class A rules and regulations and ANSI C63 4 2014 rules to limit the...

Страница 32: ...KSwitch D1 UGP Unmanaged Gigabit PoE Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 32 Figure 16 Mechanical Dimensions 2 port AC version...

Страница 33: ...ariant sources power without a PoE PD device connection Only connect the switch to an external power supply providing the voltage type AC or DC and the input power max current specified on the Kontron...

Страница 34: ...ge sufficiently Failure to observe this required off state time may mean that parts of the switch or peripherals work incorrectly or suffer a reduction of MTBF The minimum off state time to allow inte...

Страница 35: ...ve gloves The switch contains no user serviceable parts For maintenance and repair return the switch the Kontron see Chapter 9 1 Returning Defective Merchandise Restricted Access The switch s intended...

Страница 36: ...ted warranty period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website http www kontron com support and services support rma information Download the RMA Re...

Страница 37: ...e statutory accident liability obligations in the event of damage caused to the product due to failure to observe the following General safety instructions for IT equipment within this user guide Warn...

Страница 38: ...Diode LPS Limited Power Source MAC Media Access Control MDI Medium Dependent Interface MDIX Medium Dependent Interface cross over MIB Management Information Base MLD Multicast Listener Discovery MSTI...

Страница 39: ...and Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications f...