The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Introduced on the S6000.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
pre-Version
6.1.1.0
Introduced on the E-Series.
Usage
Information
The following describes the
show ntp status
command shown in the Example
below.
Field
Description
“Clock is...”
States whether or not the switch clock is synchronized,
which NTP stratum the system is assigned and the IP
address of the NTP peer.
“frequency is...”
Displays the frequency (in ppm), stability (in ppm) and
precision (in Hertz) of the clock in this system.
“reference time
is...”
Displays the reference time stamp.
“clock offset is...”
Displays the system offset to the synchronized peer and the
time delay on the path to the NTP root clock.
“root dispersion
is...”
Displays the root and path dispersion.
“peer mode is...”
State what NTP mode the switch is. This should be Client
mode.
Example
Dell#sh ntp status
Clock is synchronized, stratum 2, reference is 100.10.10.10
frequency is -32.000 ppm, stability is 15.156 ppm, precision
is 4294967290
reference time is BC242FD5.C7C5C000 (10:15:49.780 UTC Mon Jan
10 2000)
clock offset is clock offset msec, root delay is 0.01656 sec
root dispersion is 0.39694 sec, peer dispersion is peer
dispersion msec
peer mode is client
Dell#
Related
Commands
— displays information on the NTP master and peer
configurations.
System Time and Date
1425
Содержание Networking S6000 System
Страница 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Страница 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Страница 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Страница 773: ...dropped in keepalive Dell Related Commands show ip cam stack unit displays the CAM table IPv4 Routing 773 ...
Страница 1319: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1319 ...
Страница 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Страница 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...