![Dell Networking S6000 System Скачать руководство пользователя страница 298](http://html.mh-extra.com/html/dell/networking-s6000-system/networking-s6000-system_reference-manual_86040298.webp)
ingress and egress direction. Flow-based monitoring conserves bandwidth by
monitoring only specified traffic instead all traffic on the interface. This feature is
particularly useful when looking for malicious traffic. It is available for Layer 2 and
Layer 3 ingress and egress traffic. You may specify traffic using standard or
extended access-lists. This mechanism copies all incoming or outgoing packets on
one port and forwards (mirrors) them to another port. The source port is the
monitored port (MD) and the destination port is the monitoring port (MG).
deny tcp (for IPv6 ACLs)
Configure a filter that drops TCP packets that match the filter criteria.
Syntax
deny tcp {
source address mask
| any | host
ipv6-address
}
[
operator port
[
port
]] {
destination address
| any | host
ipv6-
address
} [
bit
] [
operator port
[
port
]] [count [byte]] [log
[interval
minutes
] [threshold-in-msgs [
count
]] [monitor]
To remove this filter, you have two choices:
• Use the
no seq sequence-number
command syntax if you know the filter’s
sequence number
• Use the
no deny tcp {
source address mask
| any | host
ipv6-
address
} {
destination address
| any | host
ipv6-address
}
command
Parameters
log
(OPTIONAL) Enter the keyword
log
to enable the triggering
of ACL log messages.
threshold-in
msgs
count
(OPTIONAL) Enter the
threshold-in-msgs
keyword
followed by a value to indicate the maximum number of ACL
logs that can be generated, exceeding which the generation
of ACL logs is terminated. with the seq, permit, or deny
commands. The threshold range is from 1 to 100..
interval
minutes
(OPTIONAL) Enter the keyword
interval
followed by the
time period in minutes at which ACL logs must be generated.
The time interval range is from 1 to 10 minutes.
monitor
(OPTIONAL) Enter the keyword
monitor
when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the monitored
interface.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is five minutes. By default,
flow-based monitoring is not enabled.
Command
Modes
ACCESS-LIST
298
Access Control Lists (ACL)
Содержание Networking S6000 System
Страница 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Страница 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Страница 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Страница 773: ...dropped in keepalive Dell Related Commands show ip cam stack unit displays the CAM table IPv4 Routing 773 ...
Страница 1319: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1319 ...
Страница 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Страница 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...