Version 8.3.7.0
Introduced on the S4810.
Version 7.8.1.0
Added support for Multi-Process OSPF.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
pre-Version
6.1.1.1
Introduced on the E-Series.
Usage
Information
The following describes the
show ip ospf
process-id
interface
command
shown in the following example.
Item
Description
GigabitEthernet...
This line identifies the interface type slot/port and the status
of the OSPF protocol on that interface.
Internet Address...
This line displays the IP address, network mask and area
assigned to this interface.
Process ID...
This line displays the OSPF Process ID, Router ID, Network
type and cost metric for this interface.
Transmit Delay...
This line displays the interface’s settings for Transmit Delay,
State, and Priority. In the State setting, BDR is Backup
Designated Router.
Designated
Router...
This line displays the ID of the Designated Router and its
interface address.
Backup
Designated...
This line displays the ID of the Backup Designated Router
and its interface address.
Timer intervals...
This line displays the interface’s timer settings for Hello
interval, Dead interval, Transmit Delay (Wait), and Retransmit
Interval.
Hello due...
This line displays the amount time until the next Hello
packet is sent out this interface.
Neighbor Count...
This line displays the number of neighbors and adjacent
neighbors. Listed below this line are the details about each
adjacent neighbor.
Example
Dell>show ip ospf int
GigabitEthernet 13/17 is up, line protocol is up
Internet Address 192.168.1.2/30, Area 0.0.0.1
Process ID 1, Router ID 192.168.253.2, Network Type
BROADCAST, Cost: 1
Transmit Delay is 1 sec, State DR, Priority 1
Designated Router (ID) 192.168.253.2, Interface address
192.168.1.2
Backup Designated Router (ID) 192.168.253.1, Interface
address 192.168.1.1
Timer intervals configured, Hello 10, Dead 40, Wait 40,
Retransmit 5
Hello due in 00:00:02
1032
Open Shortest Path First (OSPFv2 and OSPFv3)
Содержание Networking S6000 System
Страница 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Страница 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Страница 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Страница 773: ...dropped in keepalive Dell Related Commands show ip cam stack unit displays the CAM table IPv4 Routing 773 ...
Страница 1319: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1319 ...
Страница 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Страница 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...