manualshive.com logo in svg
background image

Single Channel Timeswitch

The Horstmann ServicePlus S11 /S11R time switch will allow up to  

3 ON/OFF settings per 24 hours and has a 1 hour manual boost and 

advance button to temporarily override current settings.

 

There is also a programming switch allowing permanent selection of:  

OFF/ON/AUTO/ALL DAY. 

 

Additionally, the ServicePlus time switch gives an advance warning  

of the annual boiler safety check due date.

ServicePlus S11 and S11R

User Operating Instructions

1

Содержание ServicePlus S11

Страница 1: ... 1 hour manual boost and advance button to temporarily override current settings There is also a programming switch allowing permanent selection of OFF ON AUTO ALL DAY Additionally the ServicePlus time switch gives an advance warning of the annual boiler safety check due date ServicePlus S11 and S11R User Operating Instructions 1 ...

Страница 2: ... 1 SET indicator RUN is the normal position 2 Time of day 3 Switch period symbol 4 SET button 5 BOOST or adjust button 6 ADVANCE or adjust button 7 ENTER button 8 SELECT button 9 SET positions 10 System ON indicator 11 PROGRAMME positions 12 BOOST symbol 13 ADVANCE symbol 14 AM PM symbol 15 PROGRAMME indicator 1 14 9 3 11 4 5 6 7 8 2 15 BOOST ADVANCE 2 12 13 10 ...

Страница 3: ...n currently OFF or switch the system OFF when currently ON To indicate the advance feature being activated ADVANCE will be shown on the display until the next programme switching time The system ON indicator will also be illuminated 3 Press BOOST button Your system will be boosted for 1 hour Press ADVANCE button once to move to the next ON OFF time At any time during a BOOST period press BOOST aga...

Страница 4: ...ill available All of the settings above will be permanent i e unaffected by programme times until alteration by the user The diagram below illustrates how to alter the setting it assumes that the programme is in the AUTO mode to begin with Press SELECT once Programme goes from AUTO to ALL DAY Timeswitch will operate from 1st ON until 3rd OFF period Press SELECT again Programme goes from ALL DAY to...

Страница 5: ...T indicator is next to CLOCK position Press the SET button until SET indicator is next to PROG position Repeat this process for 2nd and 3rd settings Use PLUS and MINUS buttons to adjust time Use PLUS and MINUS buttons to adjust 1st ON time Press the SET button until SET indicator is returned to RUN position Use PLUS and MINUS buttons to adjust 1st OFF time Press ENTER Press ENTER Press ENTER Press...

Страница 6: ...en release the buttons and the programmer will return to preset factory settings General Information BATTERY The programmer is fitted with a non rechargeable long life battery which will maintain the programmed time settings for a minimum of ten months with the supply disconnected THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT During power interruptions the disp...

Страница 7: ...ermanently off The time on the programmer must be correct Some types have to be adjusted in Spring and Autumn at the changes between Greenwich Mean Time and British Summer Time You may be able to temporarily adjust the heating programme for example Override Advance or Boost These are explained in the manufacturer s instructions The heating will not work if the room thermostat has switched the heat...

Страница 8: ...Email sales horstmann co uk Website www horstmann co uk Horstmann Controls Limited Bristol BS4 1UP Leaflet number P82510 Issue 2 8 ...

Отзывы: