These fiber optic safety switches are intended to be used with PICO-GUARD series controllers in 

personnel safety and equipment-protection applications.

Features and Description

•   Compact, non-contact, easy-to-install means of interlocking doors, guards, gates, and covers
•  Uses Banner 2.2 mm OD plastic fiber optic cable (1 mm core)
•   Designed to meet Safety Category 4 applications with one switch pair per guard (per ISO13849-1)
•  Impact- and chemically-resistant stainless steel and glass construction with PTFE-coated fiber
•  Environmental rating of IEC IP67
•   Attenuator available (see p/n 109910) for reducing excess gain in short-run applications
•  Splice available for easy connection of two fiber sections (see p/n 109910) 

Operating Distance

1-50 mm (0.04" - 2") max.

Switching Distance

See Figure 1.

Mounting

Holes for M6 screws (mounting hardware not included)

Construction

316 Stainless steel housing, glass window, PTFE sheathed plastic fiber

Temperature Range

0˚ to +70˚ C (+32˚ to 158˚F)

Max. Relative Humidity

95% (non-condensing)

Environmental Rating

IEC IP67

Refer to PICO-GUARD Controller Manual 

(p/n 69761) and PICO-GUARD Application 

and Design Guide (p/n 69763) for complete 

installation and operation information.

Dimensions

Warning ... 

Avoid 

Misapplication of this Product

PICO-GUARD optical elements 
must be properly installed and 

interfaced with a PICO-GUARD Fiber Optic 
Controller to be considered a safeguard. 

See the PICO-GUARD Controller Instruction 
Manual (p/n 69761) and the PICO-GUARD 
Application and Design Guide (p/n 69763) 
for complete installation instructions, 
maintenance instructions, and application 
limitations.

Use of a Banner PICO-GUARD Fiber Optic 
Safety Interlock Switch is generally not 
allowed for:
  •   Establishing a beam for presence-sensing  
    safeguarding (e.g., perimeter guarding),
  •   Linear (parallel) movement along the   
    optical axis (see Figure 2 and the 
    Application and Design Guide), or
  •   Machinery with long stopping time and  
    without a guard-locking mechanism.
Follow all installation and maintenance 
instructions with extreme care. 

The user is 

responsible for following all local, state, and 
national laws, rules, codes, and regulations 
relating to the use of this safeguarding 
system in any particular application.

!

Specifications

Model

Fiber Length

 

SFI-D1EDPXT6

 

1.8 m (6')

 

SFI-D1EDPXT15

 

4.5 m (15')

 

SFI-D1EDPXT30

 

9.0 m (30')

 

SFI-D1EDPXT50

 

15.3 m (50')

 

SFI-A1ED

Models

MM

 

MM

 

MM

 

MM

 

MM

 

MM

 

ŒMM

 CSINK

MM

MM

 

MM

 

MM

 

!CCOMMODATES

-HARDWARE

MM

 

MM

 

MM

 

MM

 

MM

 

MM

 

!CCOMMODATES

-HARDWARE

’MM

 CSINK

MM

 

MM

 

MM

 

Model SFI-A1ED

SFI-D1EDPXT.. Models