Chapter 109 Troubleshooting
OLT2406 User’s Guide
730
After you have resolved the issues on the rogue ONT, you can use the
no O7-state <
ont-serial-
number
>
command to have the OLT reaccept the ONT’s traffic.
109.2 Error Logs Troubleshooting
Use
show logging
to display all logs. For example:
This table describes the format of a log message.
This table lists the log severity levels from high to low.
OLT2406(config)#
interface olt pon-5-1
OLT2406(config-rogue)#
no O7-state 414C434C00050017
OLT2406# sh logging
1 Mar 20 12:59:19 IN authentication: User admin login
2 Mar 20 12:23:06 IN authentication: User admin login
3 Mar 20 12:19:09 IN system: [poncard-5 ] Restore config ready
4 Mar 20 12:19:07 DE interface: Port ge-5-4 link up
5 Mar 20 12:19:07 DE interface: Port ge-5-3 link up
6 Mar 20 12:19:07 DE interface: Port ge-5-2 link up
7 Mar 20 12:19:06 DE interface: Port ge-5-4 link down
8 Mar 20 12:19:06 DE interface: Port ge-5-3 link down
9 Mar 20 12:19:06 DE interface: Port ge-5-2 link down
10 Mar 20 12:19:06 IN system: [poncard-5 ] Ready to restore cfg
11 Mar 20 12:19:05 IN system: [poncard-5 ] pon bind success.
12 Mar 20 12:19:02 IN system: [poncard-5 ] Downloading...
13 Mar 20 12:19:02 IN system: [linecard-5 ] Detected
14 Mar 20 12:18:26 DE interface: Port ge-5-4 link up
15 Mar 20 12:18:26 DE interface: Port ge-5-3 link up
16 Mar 20 12:18:26 DE interface: Port ge-5-2 link up
17 Mar 20 12:18:26 DE interface: Port ge-5-4 link down
18 Mar 20 12:18:26 DE interface: Port ge-5-3 link down
19 Mar 20 12:18:26 DE interface: Port ge-5-2 link down
Table 382 A Log Message Format
INDEX DATE AND TIME
SEVERITY
CATEGORY
MESSAGE CONTENT
2
Sep 25 10:46:49
CR
system:
System voltage has recovered to normal state
Table 383 Log Severity Levels
CODE SEVERITY
0
EM: Emergency, the system is unusable.
1
AL: Alert, action must be taken immediately.
2
CR: Critical, the system condition is critical.
3
ER: Error, there is an error condition on the system.
4
WA: Warning, there is a warning condition on the system.
5
NO: Notice, there is a normal but significant condition on the system.
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Page 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Page 393: ...393 PART III CLI Commands...
Page 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Page 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...