Chapter 107 Error-Disable Recovery
OLT2406 User’s Guide
722
C
HAPTER
107
Error-Disable Recovery
107.1 Error-Disable Recovery Overview
Some features, such as loop guard or CPU protection, allow the OLT to shut down a port or discard
specific packets on a port when an error is detected on the port. For example, if the OLT detects that
packets sent out the port(s) loop back to the OLT, the OLT can shut down the port(s) automatically. After
that, you need to enable the port(s) or allow the packets on a port manually via the web configurator
or the commands. With error-disable recovery, you can set the disabled port(s) to become active or
start receiving the packets again after the time interval you specify.
107.2 Error-Disable Recovery Commands
Use these commands to configure the error disable features on the OLT.
Table 380 Error Disable Recovery Commands
COMMAND
DESCRIPTION
M
P
errdisable detect cause <
reason
>
Sets the OLT to detect if the number of ARP,
BPDU, IGMP, PPPoE, FTP, or ICMP packets
exceeds the rate limit on port(s).
reason
:[ARP][BPDU][IGMP][PPPoE][FT
P][ICMP] [SNMP]
C
13
errdisable detect cause help
Sets the action that the OLT takes when the
number of ARP, BPDU, IGMP, PPPoE, FTP, or ICMP
packets exceeds the rate limit on port(s).
C
13
errdisable recovery cause <
reason
>
Enables the recovery timer for the specified
feature that causes the OLT to shut down port(s).
C
13
errdisable recovery cause help
Sets how many seconds the OLT waits before
enabling the port(s) which was shut down.
C
13
errdisable recovery cause
Enables the recovery timer on the OLT.
C
13
no errdisable detect cause <
reason
>
Disables the recovery timer for the specified
feature that causes the OLT to shut down a port.
C
13
no errdisable recovery
Turns off the disabled port recovery function on
the OLT.
C
13
no errdisable recovery cause
<
reason
>
Disables the recovery timer for the specified
feature that causes the OLT to shut down a port.
C
13
show errdisable
Displays which port(s) are detected (by Error
Disable), the mode of the ports, and which
packets are being detected.
E
3
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Page 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Page 393: ...393 PART III CLI Commands...
Page 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Page 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...