Chapter 27 IP Source Guard
OLT2406 User’s Guide
240
The following table describes the labels in this screen.
27.9.2 ARP Inspection VLAN Configure
Use this screen to enable ARP inspection on each VLAN and to specify when the OLT generates log
messages for receiving ARP packets from each VLAN. To open this screen, click
Advanced Application
> IP Source Guard > ARP Inspection > Configure > VLAN
.
Table 91 Advanced Application > IP Source Guard > ARP Inspection > Configure > Port
LABEL
DESCRIPTION
Port
This field displays the port number. If you configure the
*
port, the settings are applied
to all of the ports.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row
first to set the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make
them.
Trusted State
Select whether this port is a trusted port (
Trusted
) or an untrusted port (
Untrusted
).
The OLT does not discard ARP packets on trusted ports for any reason.
The OLT discards ARP packets on untrusted ports in the following situations:
• The sender’s information in the ARP packet does not match any of the current
bindings.
• The rate at which ARP packets arrive is too high. You can specify the maximum
rate at which ARP packets can arrive on untrusted ports.
Limit
These settings have no effect on trusted ports.
Rate (pps)
Specify the maximum rate (1-2048 packets per second) at which the OLT receives ARP
packets from each port. The OLT discards any additional ARP packets. Enter 0 to
disable this limit.
Burst interval
(seconds)
The burst interval is the length of time over which the rate of ARP packets is monitored
for each port. For example, if the rate is 15 pps and the burst interval is 1 second, then
the OLT accepts a maximum of 15 ARP packets in every one-second interval. If the
burst interval is 5 seconds, then the OLT accepts a maximum of 75 ARP packets in every
five-second interval.
Enter the length (1-15 seconds) of the burst interval.
Apply
Click
Apply
to save your changes to the OLT’s run-time memory. The OLT loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation
panel to save your changes to the non-volatile memory when you are done
configuring.
Cancel
Click this to reset the values in this screen to their last-saved values.
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Page 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Page 393: ...393 PART III CLI Commands...
Page 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Page 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...