
Chapter 85 Access Control
OLT2406 User’s Guide
612
An OID (Object ID) that begins with “
1.3.6.1.4.1.890.1.5.17
” is defined in private MIBs. Otherwise, it is a
standard MIB OID.
The OIDs beginning with “
1.3.6.1.4.1.890.1.5.17.4
” are specific to the OLT2406.
Table 318 SNMP System Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
coldstart
coldStart
1.3.6.1.6.3.1.1.5.1
This trap is sent when the OLT is turned on.
warmstart
warmStart
1.3.6.1.6.3.1.1.5.2
This trap is sent when the OLT restarts.
fanspeed
FanSpeedEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when the fan speed goes
above or below the normal operating
range.
FanSpeedEventClear
1.3.6.1.4.1.890.1.5.17.4.31.2.2
This trap is sent when the fan speed returns
to the normal operating range.
temperature
TemperatureEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when the temperature goes
above or below the normal operating
range.
TemperatureEventClear
1.3.6.1.4.1.890.1.5.17.4.31.2.2
This trap is sent when the temperature
returns to the normal operating range.
voltage
VoltageEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when the voltage goes
above or below the normal operating
range.
VoltageEventClear
1.3.6.1.4.1.890.1.5.17.4.31.2.2
This trap is sent when the voltage returns to
the normal operating range.
reset
UncontrolledResetEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when the OLT automatically
resets.
ControlledResetEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when the OLT resets by an
administrator through a management
interface.
RebootEvent
1.3.6.1.4.1.890.1.5.1.1.2
This trap is sent when the OLT reboots by an
administrator through a management
interface.
timesync
RTCNotUpdatedEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when the OLT fails to get the
time and date from a time server.
RTCNotUpdatedEventClear
1.3.6.1.4.1.890.1.5.17.4.31.2.2
This trap is sent when the OLT gets the time
and date from a time server.
intrusionlock
IntrusionLockEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when intrusion lock occurs on
a port.
loopguard
LoopguardEventOn
1.3.6.1.4.1.890.1.5.17.4.31.2.1
This trap is sent when loopguard shuts down
a port.
Table 319 SNMP Interface Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
linkup
linkUp
1.3.6.1.6.3.1.1.5.4
This trap is sent when the Ethernet
link is up.
LinkDownEventClear
1.3.6.1.4.1.890.1.5.17.4.31.2.2
This trap is sent when the Ethernet
link is up.
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Page 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Page 393: ...393 PART III CLI Commands...
Page 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Page 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...