Chapter 95 CFM Commands
OLT2406 User’s Guide
654
mhf-creation < none | default |
explicit>
Sets MHF (MIP Half Function).
Select
none
and no MIP can be created
automatically for this MA.
Select
default
to automatically create MIPs for
this MA and on the ports belonging to this MA’s
VLAN when there are no lower configured MD
levels or there is an MEP at the next lower
configured MD level on the port.
Select
explicit
to automatically create MIPs
for this MA and on the ports belonging to this
MA’s VLAN only when there is an MEP at the
next lower configured MD level on the port.
C
13
remote-mep <1-8091>
Sets a remote MEP in an MA.
C
13
remote-mep <1-8091> mac <
mac-
address
>
Sets a remote MEP with a specified MAC
address.
C
13
no mep <1-8091>
Deletes a specified MEP.
C
13
no mep <1-8091> cc-enable
Disallows an MEP sending Connectivity Check
Messages (CCMs) periodically to other MEPs.
C
13
no mep <1-8091> inactive
Enables an MEP.
C
13
ethernet cfm management-address-
domain ip
Configures the management IP address as the
CFM management IP address.
C
13
ethernet cfm management-address-
domain ip <
ip-addr
>
Sets the OLT to carry the host name and
management IP address for the VLAN to which
an MEP belongs or the specified IP address in
CFM packets.
This helps you to easily identify a remote MEP by
its host name and management IP address
showed in the link trace database and MEP-
CCM database.
C
13
interface port-channel <
aid
>
Enters config-interface mode for configuring the
specified port(s).
<
aid
>: <ge|msc|pon>-<slot>-<port>
C
13
ethernet cfm virtual-mac <
mac-
addr
>
Assigns a virtual MAC address(es) to the
specified port(s) so that each specified port can
have its own MAC address for CFM.
You cannot use the
copy running-config
interface port-channel
command to copy
the virtual MAC address from the specified port
to other ports.
C
13
exit
Exits from the command.
C
13
show ethernet cfm linktrace
Displays the CFM link trace database
information.
E
13
show ethernet cfm local
Displays the detailed settings of the configured
MD(s) and MA(s).
E
13
show ethernet cfm virtual-mac
Displays all virtual MAC addresses.
E
13
show ethernet cfm virtual-mac port
<
aid
>
Displays the MAC address(es) of the specified
port(s).
E
13
Table 351 CFM Commands (continued)
COMMAND
DESCRIPTION
M
P
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Page 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Page 393: ...393 PART III CLI Commands...
Page 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Page 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...