Chapter 37 OLT Registration
OLT2406 User’s Guide
300
37.5 The OLT Status Screen
Use this screen to view the OLT status. Click
OLT Status
in the
Advanced Application
>
OLT Registration
screen to display the screen as shown.
Figure 183
Advanced Application > OLT Registration > OLT Status
The following table describes the labels in this screen.
OOS-SB
This shows how many ONTs connected to the GPON interface have an Out Of Service - StandBy
status.
OOS-DG
This shows how many ONTs connected to the GPON interface have an Out Of Service - Dying Gasp
status.
OOS-LS
This shows how many ONTs connected to the GPON interface have an Out Of Service - Loss Of
Signal status.
OOS-NR
This shows how many ONTs connected to the GPON interface have an Out Of Service - Not
Registered status.
OOS-CD
This shows how many ONTs connected to the GPON interface have an Out Of Service - OMCC
Down status.
OOS-TM
This shows how many ONTs connected to the GPON interface have an Out Of Service - Type
Mismatch.
OOS-NP
This shows how many ONTs connected to the GPON interface have an Out Of Service - Not
Provisioned status.
OOS-PF
This shows how many ONTs connected to the GPON interface have an Out Of Service - Provision
Fail status.
Table 129 Advanced Application > OLT Registration > ONT Summary (continued)
LABEL
DESCRIPTION
Table 130 Advanced Application > OLT Registration > OLT Status
LABEL
DESCRIPTION
PON AID
This is the identifier for the GPON interface.
State
This shows the GPON interface’s ONT link status. This shows
ACTIVE
if the ONT is connected to the
PON port.
Key_Exchang
e
This shows whether the key exchange is enabled or disabled on the PON port.
SN_Acq
This shows whether serial number acquisition is enabled or disabled on the PON port. It is enabled
by default.
Rogue
Detect
This shows whether rogue ONT detection is enabled or disabled on the PON port. In some
circumstances, some ONTs may be out of the OLT’s control and impact other ONUs’ data
transmission. The OLT can be set to perform rogue detection to diagnose it. Note that the ONT must
support rogue detection for this to work.
Please use the rogue detection commands to start or stop the diagnosis.
Interval
SN_Acq
This shows the interval at which the OLT broadcasts a Serial Number Acquisition message to ONTs
connected to a PON port, in units of ms. When an ONT receives the SN ACQ message, it sends a
DISCOVERED SN message with its serial number back to the OLT. The value is 8000 ms by default.
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Page 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Page 393: ...393 PART III CLI Commands...
Page 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Page 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...