Chapter 26 AAA
OLT2406 User’s Guide
218
The following table describes the labels in this screen.
26.5 AAA Setup
Use this screen to configure authentication, authorization and accounting settings on the OLT. Click on
the
AAA Setup
link in the
AAA
screen to view the screen as shown.
Table 77 Advanced Application > AAA > Server Setup
LABEL
DESCRIPTION
Authentication
Server
Use this section to configure your authentication settings.
Mode
This field is only valid if you configure multiple servers.
Select
index-priority
and the OLT tries to authenticate with the first configured server,
if the server does not respond then the OLT tries to authenticate with the second
server.
Select
round-robin
to alternate between the servers that it sends authentication
requests to.
Timeout
Specify the amount of time in seconds (between 1 to 1000) that the OLT waits for an
authentication request response from the server.
If you are using
index-priority
for your authentication and you are using two servers
then the timeout value is divided between the two servers. For example, if you set
the timeout value to 30 seconds, then the OLT waits for a response from the first
server for 15 seconds and then tries the second server.
Index
This is a read-only number representing a server entry.
IP Address
Enter the IP address of an external server in dotted decimal notation.
TCP Port
The default port of a server for authentication is
49
. You need not change this value
unless your network administrator instructs you to do so.
Shared Secret
Specify a password (up to 32 alphanumeric characters) as the key to be shared between the
external server and the OLT. This key is not sent over the network. This key must be the
same on the external server and the OLT.
Delete
Check this box if you want to remove an existing server entry from the OLT. This entry
is deleted when you click
Apply
.
Accounting
Server
Use this section to configure your accounting settings.
Timeout
Specify the amount of time in seconds (between 1 to 1000) that the OLT waits for an
accounting request response from the server.
Index
This is a read-only number representing a accounting server entry.
IP Address
Enter the IP address of an external accounting server in dotted decimal notation.
TCP Port
The default port of a accounting server is
49
. You need not change this value unless
your network administrator instructs you to do so.
Shared Secret
Specify a password (up to 32 alphanumeric characters) as the key to be shared between the
external accounting server and the OLT. This key is not sent over the network. This key
must be the same on the external accounting server and the OLT.
Delete
Check this box if you want to remove an existing accounting server entry from the
OLT. This entry is deleted when you click
Apply
.
Apply
Click
Apply
to save your changes to the OLT’s run-time memory. The OLT loses these changes if
it is turned off or loses power, so use the
Save
link on the top navigation panel to save your
changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...