Chapter 75 VLAN Stacking and Translation
OLT2406 User’s Guide
532
vlan-translation
name
<
name
>
[ing-ovid <
vid
>] [ing-ivid
<
vid
>] [ing-opri <
pri
>] [ing-
ipri <
pri
>] [egr-svid <
vid
>]
[egr-cvid <
vid
>]
[egr-spri <
pri
>] [egr-cpri
<
pri
>] [N1map <
group
>] [cross-
connect <enable|disable>]
[cross-port <
aid
>] [active
<on|off>]
Creates a VLAN translation rule (with the
specified name) on the port.
vid
: VLAN ID, 1 ~ 4094.
pri
: Priority (0 ~ 7), lower numbers are higher
priority.
The ingress parameters (
ing-xxxx
) mean the
VLAN tag of the target traffic to which the OLT
applies this translation rule. That is the ingress
(incoming, upstream) packets coming from the
subscribers.
ing-ovid <
vid
>
: The outer tag of incoming
packets.
ing-ivid <
vid
>
: The inner tag of incoming
packets.
ing-opri <
pri
>
: The outer priority of incoming
packets.
ing-ipri <
pri
>
: The inner priority of incoming
packets.
The OLT applies the egress parameters (
egr-
xxxx)
to the egress (outgoing) packets going
out the uplink ports towards the backbone
network.
egr-svid <
vid
>
: The Service provider VID
(outer) tag of outgoing packets.
egr-cvid <
vid
>
: The Customer VID (inner) tag
of outgoing packets.
egr-spri <
vid
>
: The Service provider (outer)
priority of outgoing packets.
C
13
egr-cpri <
vid
>
: The Customer (inner) priority
of outgoing packets.
N1map <
group
>
: Use a group ID (1 ~ 16384) to
map multiple ingress (ing) VLANs to one egress
(egr) VLAN. All VLAN translation rules with the
same N1map group ID must use the same egress
VLAN.
cross-connect <enable|disable>
:
Connect this rule’s VLAN on this port to another
port. The OLT ignores the MAC address of ingress
packets and forwards them by VID to the cross-
connected port. The OLT does not need to learn
a destination MAC address before forwarding
packets for it to the cross-connected port. No
other ports can be members of the VLAN. You
cannot use N1map and cross connect in the
same VLAN translation rule.
cross-port <
aid
>
: Cross connect connects
this rule’s VLAN on this port to another port.
Specify the other port here.
active <on|off>
: Turns the VLAN translation
rule on or off.
C
13
Table 272 VLAN Translation Commands (continued)
COMMAND
DESCRIPTION
M
P
Summary of Contents for OLT2406
Page 4: ...Document Conventions OLT2406 User s Guide 4 Desktop Laptop Switch IP Phone Smart T V...
Page 32: ...Table of Contents OLT2406 User s Guide 32 Index 758...
Page 33: ...33 PART I Introduction and Hardware Installation...
Page 63: ...63 PART II Web Configurator...
Page 179: ...Chapter 21 Classifier OLT2406 User s Guide 179 Figure 112 Classifier Example...
Page 182: ...Chapter 22 Policy Rule OLT2406 User s Guide 182 Figure 113 Advanced Application Policy Rule...
Page 186: ...Chapter 22 Policy Rule OLT2406 User s Guide 186 Figure 114 Policy Example...
Page 248: ...Chapter 28 Loop Guard OLT2406 User s Guide 248 Figure 151 Advanced Application Loop Guard...
Page 393: ...393 PART III CLI Commands...
Page 581: ...Chapter 78 VoIP OLT2406 User s Guide 581...
Page 725: ...725 PART IV Troubleshooting Specifications Appendices and Index...