SD20-G Series
209
Rising edge
High
Po438-Po445
Low
Valid
Falling edge
High
Po438-Po445
Low
Valid
Normal DI terminal filter setting
If there is interference in terminal signal, users can carry on filter processing by setting Po438~Po444.
Po438
DI1 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Po439
DI2 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Po440
DI3 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Po441
DI4 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Po442
DI5 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Po443
DI6 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Po444
DI7 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Po445
DI8 filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate effect
Summary of Contents for SD20-G Series
Page 35: ...SD20 G Series 35 M3 structure Fig 3 1 5 Servo drive structure 3...
Page 36: ...SD20 G Series 36 ML3 structure 118 5 5 7 5 93 297 8 223 118 93 0 5 12 5 7 5 4 M4...
Page 38: ...SD20 G Series 38 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5...
Page 39: ...SD20 G Series 39 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6...
Page 40: ...SD20 G Series 40 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7...
Page 182: ...SD20 G Series 182 Fig 6 4 44SD20E Cam internal frameworkdiagram...