SD20-G Series
292
Po216
Forward/reverse run prohibited torque setting Torque
Setting range
Setting unit
Mfr’s value
Effect
0~1
N/A
1
Effective Immediate
0: Actual limit torque is Po207 1:Torque limit is 0
Po217
1
st
Notch filter center frequency Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
50~30000
Hz
2000
Effective Immediate
Po218
1
st
Notch filter width Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0~30000
Hz
5
Effective Immediate
Po219
1
st
Notch filter depth Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0~100
N/A
0
Effective Immediate
Please refer to 7.4.
Po220
2
nd
Notch filter center frequency Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
50~30000
Hz
2000
Effective Immediate
Please refer to 7.4.
Po221
2
nd
Notch filter width Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0~30000
Hz
5
Effective Immediate
Po222
2
nd
Notch filter depth Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0~100
N/A
0
Effective Immediate
Po223
3
rd
Notch filter center frequency Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
50~30000
Hz
2000
Effective Immediate
Po224
3
rd
Notch filter width Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
Summary of Contents for SD20-G Series
Page 35: ...SD20 G Series 35 M3 structure Fig 3 1 5 Servo drive structure 3...
Page 36: ...SD20 G Series 36 ML3 structure 118 5 5 7 5 93 297 8 223 118 93 0 5 12 5 7 5 4 M4...
Page 38: ...SD20 G Series 38 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5...
Page 39: ...SD20 G Series 39 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6...
Page 40: ...SD20 G Series 40 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7...
Page 182: ...SD20 G Series 182 Fig 6 4 44SD20E Cam internal frameworkdiagram...