Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
2026
pwe3-stm1oc3-s-
mute-override-
alarm
Alarm Equipment
SFP is muted on TDM-
LIC STM1/OC3 port
Warning
2027
pwe3-stm1oc3-s-
sfp-absent-alarm
Alarm Equipment
SFP absent in TDM-LIC
STM1/OC3 port
Critical
1.
SFP is not properly
installed.
2.
SFP is faulty.
1.
Install SFP properly.
2.
Replace the card.
2028
pwe3-stm1oc3-s-
sfp-failure-alarm
Alarm Equipment
SFP failure on TDM-LIC
STM1/OC3 port
Critical
1.
SFP is not properly
installed.
2.
SFP is faulty.
1.
Install SFP properly.
2.
Replace the card.
2029
pwe3-stm1oc3-s-
sfp-tx-fail-alarm
Alarm Equipment
SFP transmit failure on
TDM-LIC STM1/OC3
port
Critical
1.
SFP is not properly
installed.
2.
SFP is faulty.
1.
Install SFP properly.
2.
Replace the card.
2030
pwe3-stm1oc3-s-
signal-degrade-
alarm
Alarm Equipment
Signal Degrade on TDM-
LIC STM1/OC3 port
Minor
1.
Line is not properly
connected.
2.
SFP is not properly
installed.
3.
SFP is faulty.
4.
External equipment
is faulty
1.
Install SFP properly.
2.
Reconnect line.
3.
Check line cables.
4.
Check external equipment.
5.