SOLIDFIRE
Getting Started Guide
FC0025 and SF-FCN-01 Fibre Channel Node
1.
Identifying the Rail Kit Contents
2.
Installing and Removing Tool-Less Rails (Square Hole or Round Hole Racks)
Locate the components for
installing the rail kit assembly:
1 - Two A7 ReadyRails II
sliding rail assemblies
2- Two hook and loop straps
(
1
). Position the left and right rail
end pieces labeled FRONT facing
inward and orient each end piece to
seat in the holes on the front side of
the vertical rack flanges.
(
2
). Align each end piece in the
bottom and top holes of the desired
U spaces.
(
3
). Engage the back end of the rail
until it fully seats on the vertical
rack flange and the latch clicks into
place. Repeat these steps to
position and seat the front end
piece on the vertical rack flange.
(
4
). To remove the rails, pull the
latch release button on the end
piece midpoint and unseat each rail.
3.
Installing and Removing Tooled Rails (Threaded Hole Racks)
4.
Installing the System in a Rack
(
1
). Remove the pins from the front
and rear mounting brackets using a
flat-tipped screwdriver.
(
2
). Pull and rotate the rail latch
subassemblies to remove them
from the mounting brackets.
(
3
). Attach the left and right
mounting rails to the front vertical
rack flanges using two pairs of
screws.
(
4
). Slide the left and right back
brackets forward against the rear
vertical rack flanges and attach
them using two pairs of screws.
(
1
). Pull the inner slide rails out of
the rack until they lock into place.
(
2
). Locate the rear rail standoff on
each side of the system and lower
them into the rear J-slots on the
slide assemblies.
(
3
)Rotate the system downward
until all the rail standoffs are seated
in the J-slots.
(
4
) Push the system inward until the
lock levers click into place. Press the
slide-release lock buttons on both
rails and slide the system into the
rack.
5.
Removing the System From the Rack
6.
Engaging and Releasing the Slam Latch
(
1
). Locate the lock levers on the
sides of the inner rails.
(
2
). Unlock each lever by rotating it
up to its release position.
(
3
). Grasp the sides of the system
firmly and pull it forward until the
rail standoffs are at the front of the
J-slots. Lift the system up and
away from the rack and place it on
a level surface.
NOTE:
For systems not equipped
with slam latches, secure the
system using screws, as described
in step 3 of this procedure.
(
1
). Facing the front, locate the slam
latch on either side of the system.
(
2
). The latches engage
automatically as the system is
pushed into the rack and are
released by pulling up on the
latches.
(
3
). To secure the system for
shipment in the rack or for other
unstable environments, locate the
hard-mount screw under each latch
and tighten each screw with a #2
Phillips screwdriver.
Notes, Cautions and Warnings
A
NOTE
indicates important information that helps you make better use of your computer.
A
CAUTION
indicates potential damage to hardware or loss of data if instructions are not followed.
A WARNING indicates a potential for property damage, personal injury or death.
WARRANTY DISCLAIMER.
THE STORAGE SYSTEM AND ANY OTHER MATERIALS, SOFTWARE, DATA AND/OR SERVICES PROVIDED BY NETAPP SOLIDFIRE ARE PROVIDED “AS IS” AND “WITH ALL
FAULTS,” AND NETAPP SOLIDFIRE EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES OF ANY KIND OR NATURE, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING, BUT NOT LIMITED TO, ANY WARRANTIES OF OPERABILITY, CONDITION, TITLE, NON-INFRINGEMENT, NON- INTERFERENCE, QUIET ENJOYMENT, VALUE,
ACCURACY OF DATA, OR QUALITY, AS WELL AS ANY WARRANTIES OF MERCHANTABILITY, SYSTEM INTEGRATION, WORKMANSHIP, SUITABILITY, FITNESS FOR A
PARTICULAR PURPOSE, OR THE ABSENCE OF ANY DEFECTS THEREIN, WHETHER LATENT OR PATENT.
Support Services for NetApp SolidFire Products: In conjunction with its initial purchase of a NetApp SolidFire Storage System, Customer purchases one year of Support and Maintenance Services,
and may purchase additional years (“Initial Support and Maintenance”). The Initial Support and Maintenance Term will commence upon delivery.
What’s In The Box
Package Contents:
1 – SolidFire FC0025 node
1 – Slide Rail Kit
1 – Getting Started Guide
2 – Power Cables
1 – End User License Agreement
NOTE:
Begin installing the rails in the allotted space that is closest to the bottom of the rack
enclosure.
NOTE:
The illustrations in this document do not represent a specific system.
NOTE:
The tooled rail mounting configuration requires eight user-supplied screws: #10-32, #12-
24, #M5, or #M6. The head diameter of the screws must be less than 10 mm (0.4”).
This is a condensed reference. Read the safety instructions in your Safety, Environmental,
and Regulatory Information booklet before you begin.
Only trained NetApp service technicians are authorized to remove the system cover and
access any of the components inside the system. Before you begin, review the safety
instructions that came with the system.