User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 786 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1758
pdc-card-
extraction-event
Event
Equipment
Power Supply was
extracted from slot
Warning
Power Supply was
extracted from slot
1759
pdc-card-insertion-
event
Event
Equipment
Power Supply was
inserted to slot
Warning
Power Supply was
inserted to slot.
1760
pdc-card-missing
Alarm Equipment
Power Supply is missing
in slot
Major
1.
Power Supply is
missing.
2.
Slot enabled when
empty.
1.
Insert Power Supply.
2.
Disable slot.
1761
pdc-over-voltage
Alarm Equipment
Over voltage
Major
System Power Voltage
higher than allowed.
NA
1762
pdc-under-voltage
Alarm Equipment
Under voltage
Major
System Power Voltage
Lower than allowed.
NA
1763
TCC-fpga-fw-not-
found
Alarm Equipment
The Main board
firmware is not found
Warning
1764
TCC-fw-load-fail
Alarm Equipment
Download Main Board
firmware has failed
Major
Firmware download was
unsuccessful.
1.
Reset board.
2.
Download software
package.
3.
Try to insert another
board.
1765
tcc-powerup-reset-
event
Event
Equipment
Main Board was reset
Warning