User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 340 of 825
Ceragon Proprietary and Confidential
7 In the
Control Interface
field, select the Control Interface. This is the interface
to which messages are transmitted when bandwidth in the monitored
interface degrades below the nominal value.
8 In the
MEL
field, select the Maintenance Level in the messages.
9 In the
Tx VLAN
field, specify the VLAN on which messages are transmitted.
Options are:
◦
Untagged.
◦
1
–
4090.
10 In the
Tx Period
field, specify how often messages are transmitted when
bandwidth is below the nominal value. Options are:
◦
4
–
One second.
◦
5
–
Ten seconds.
◦
6
–
One minute.
11 In the
Holdoff Time
field, specify the amount of time the system waits when
bandwidth degradation occurs, before transmitting a message. If the
bandwidth is below the nominal value when the holdoff period ends, the
system starts transmitting messages.
12 In the
Monitoring Interval
field, select the interval for which a weighted
average of the bandwidth readings is calculated.
13 Click
Apply
, then
Close
.
describes the status (read-only) fields in the ABN Configuration and
Status table.
Table 56: ABN Status Parameters
Parameter
Definition
Nominal BW
The nominal bandwidth of the link.
Current BW
The weighted average of the bandwidth readings taken during the last Monitoring Interval.
Version
The ABN version used.
8.1.3
Editing an ABN Entity
To edit an ABN entity:
1 Select
Ethernet > Protocols > Bandwidth Notification
. The Bandwidth
Notification page opens (
2 Select the ABN entity in the Bandwidth Notification page.
3 Click
Edit
. The Bandwidth Notification - Edit page opens.
The Edit page is similar to the Bandwidth Notification
–
Add page (
However, the
Control interface
and
Monitored interface
parameters are
read-only, and additional read-only parameters display the
Nominal BW
,
the
Current BW
, and the
Version
.
4 Edit the ABN entity attributes, as described in
5 Click
Apply
, then
Close
.