User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 776 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1610
rsl-degradation-
threshold-out-of-
range
Alarm Equipment
Radio Receive Signal
Level is below the
configured threshold
Warning
RSL is very low due to:
1.
Weather conditions,
obstruction in
antenna line of sight,
antennae alignment.
2.
Configured threshold
needs to be
adjusted.2.
1.
Check for obstruction in
link path.
2.
Check the antennae
alignment and link
planning.
3.
Recalculate the Path Loss
and set the threshold
accordingly.
4.
Check link settings - Tx
Power and Tx Frequency.
5.
Hardware problem.
1651
atpc-override
Alarm Communications
ATPC overridden: Tx
level has been equal to
the Max Tx level for a
longer time than
allowed
Warning
Actual transmitted signal
level has been at its
maximum value for
longer than allowed. This
is probably caused by a
configuration error or link
planning error.
Correct the transmission levels.
The alarm will be cleared only
upon manual clearing.
1697
radio-unit-
extreme-
temperature
Alarm Equipment
Radio unit extreme
temperature
Warning
1.
Installation
conditions.
2.
Defective RFU.
1.
Check installation
conditions.
2.
Verify operation as per
product's specs.
3.
Replace RFU.