User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 797 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
2041
pwe3-card-group-
s-config-mismatch
Alarm Equipment
TDM-LIC card protection
configuration mismatch
Major
The configuration
between the TDM-LIC
card protection members
is not aligned
Apply a copy-to-mate
command to copy the
configuration from the
required TDM-LIC to the other
one
2042
pwe3-card-group-
s-lockout
Alarm Equipment
TDM-LIC card protection
group lockout command
is on
Minor
The user has issued a
lockout command
Clear the lockout command
2043
pwe3-card-group-
s-no-mate
Alarm Equipment
A member of TDM-LIC
card protection group is
missing
Minor
TDM-LIC card is not
installed in the shelf
Install the missing TDM-LIC
card
2044
pwe3-card-group-
s-protection-
switch-evt
Event
Equipment
TDM-LIC card protection
switch over, priority
Warning
1.
LOS alarm on a STM1
interface of the
TDM-LIC card
protection group
member;
2.
A TDM-LIC card
protection group
member was
disabled or pulled
out of the shelf
1.
Check line cables.
2.
Check external equipment.
2045
pwe3-vc12vt15-s-
lop-alarm
Alarm Equipment
Loss Of Pointer (LOP)
received on TDM-LIC
VC12/VT1.5
Minor
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.