User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 779 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1705
delay-calibration-
failure-2
Alarm Equipment
RFU delay calibration
failure 2
Warning
Calibration cannot be
completed due to notch
detection
Enter delay calibration value
manually.
1706
extreme-temp-
cond
Alarm Equipment
RFU extreme
temperature
Warning
1.
Installation
conditions.
2.
Defective RFU.
1.
Check installation
conditions.
2.
Verify operation as per
product's specs.
3.
Replace RFU.
1707
radio-unit-abc-
incompatible-rfu
Alarm Equipment
RFU is incompatible
with ABC configuration
Warning
The RFU type does not
support the type of Multi-
Carrier ABC the user has
configured.
Replace the RFU with an RFU
type that supports the
configured Multi-Carrier ABC
type.
1708
freq-set-
automatically
Event
Equipment
RFU frequency was set
automatically
Warning
Defective RFU
1.
Check if problem repeats
and if errors/alarms
reported.
2.
Replace RFU.
1709
hardware-failure-1
Alarm Equipment
RFU hardware failure 1
Critical
Defective RFU.
Replace RFU.
1710
hardware-failure-2
Alarm Equipment
RFU hardware failure 2
Critical
Defective RFU.
Replace RFU.