User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 170 of 825
Ceragon Proprietary and Confidential
11 Configure Unit Protection, according to the instructions in
Protection with HSB Radio Protection (External Protection)
12 On the active IP-20 unit, mute the transmitter of radio carrier 2. For
instructions, see
Configuring the Radio Parameters
13 Perform Copy to Mate. See Step 5 in
Configuring HSB Radio Protection
Important Note:
It is crucial to ensure that the port connected to the Diversity
antenna is muted in each IP-20 unit. If you perform Copy to Mate after
configuring unit protection, as indicated above, the mute
configuration will be copied to the standby unit. If you mute the
interface before configuring unit protection, you must make sure to
manually
mute the interface on
both
IP-20 units. Otherwise,
configuring unit protection will override the mute configuration.