User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 788 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1772
xpic-data-los
Alarm Equipment
Radio XPIC sync loss
Major
Signalling between RMCs
(Radio Modem Cards) for
XPIC functionality has
failed
1.
Check that the RMCs are in
allowed slots.
2.
Populate the RMCs in
different allowed location
in the chassis.
3.
Replace RMC/s.
4.
Replace chassis.
1773
early-warning
Alarm Communications
Radio early warning.
Warning
The estimated radio BER
(Bit Error Rate) is above
10E-12.
5.
Check link performance.
6.
Check IF cable, and replace
if required.
7.
Replace XCVR.
8.
Replace RMC.
1774
sw-download-
incompatible-rfu
Alarm Equipment
RFU software download
cannot be initiated.
Critical
The hardware of the
XCVR is OK, but is it
running with METRO
radio application.
1.
Upgrade the XCVR
software application via
XPAND-IP and then
reinitiate software
download..
1775
hw-incompatible-
rfu
Alarm Equipment
RFU software download
is not possible.
Critical
Wrong type of XCVR, the
XCVR hardware is
METRO.
Replace the XCVR
1776
pll-rmc
Alarm Equipment
RMC hardware failure.
Major
RMC hardware failure of
the clock distributor.
Replace the RMC.