User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 559 of 825
Ceragon Proprietary and Confidential
Table 127: Entering Ethernet Service View CLI Parameters
Parameter
Input Type
Permitted Values
Description
sid
Number
Any unused value
from 1-256
A unique ID for the
service. Once you have
added the service, you
cannot change the Service
ID. Service ID 257 is
reserved for a pre-defined
management service.
The following command enters service view for the service with Service ID 10:
root> ethernet service sid 10
The following prompt appears:
service[10]>
17.1.3.3
Showing Service Details (CLI)
To display the attributes of a service, go to service view for the service and enter
the following command:
service[SID]>service info show
For example:
service[1]>service info show
service info:
service id: 1
service type: p2p
service admin: operational
Maximal MAC address learning entries: 131072
default cos: 0
cos mode: preserve-sp-cos-decision
EVC id: N.A.
EVC description: N.A.
split horizon group: disable
configured multicast grouping: no
service[1]>
To display the attributes of a service and its service points, go to service view for
the service and enter the following command:
service[SID]>service detailed-info show