Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
5109
main-board-non-
fips-alarm
Alarm Equipment
Main Board is not FIPS
certified
Critical
Main Board used is not
FIPS certified
Use a FIPS-certified TCC.
5110
radio-non-fips-
alarm
Alarm Equipment
Radio card is not FIPS
certified
Major
Radio Card used is not
FIPS certified
Use a FIPS-certified RMC.
5111
aes-self-test-fail-
alarm
Alarm Equipment
Radio crypto module fail Critical
FIPS Radio Encryption
Self-Test failed
Use different FIPS supported
radio card
5112
hw-not-supported-
alarm
Alarm Equipment
Radio Encryption not
supported
Major
No Payload Encryption
Activation Key inserted
Insert suitable Activation Key
and reboot the unit
30007
Clock-source-
sharing-failure-
event
Event
Equipment
Clock source sharing
failure
Critical
1.
Faulty coaxial cable
between master and
slave RFUs.
2.
Hardware failure in
Master RFU.
3.
Hardware failure in
Slave RFU.
1.
Try re-initiation of MIMO.
If still fails:
2.
Replace faulty coaxial
cable and reset Master
RFU.
3.
Replace faulty RFU.
31000
Insufficient-
conditions-for-
MIMO-alarm
Alarm Equipment
Insufficient conditions
for MIMO
Critical
1.
Insufficient
conditions for MIMO.
2.
Hardware failure.
1.
Make sure all cables
between master and slave
are connected (MIMO 4x4
only).
2.
Replace faulty units and
check that cables are
plugged.