User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 739 of 825
Ceragon Proprietary and Confidential
23.5.2
Management Port (FE-Standard) and Protection (FE-Non-Standard)
Table 250: IP-20C-HP Management Interface - RJ-45 Pinouts
Pin no.
Description
Management - Standard 100Base-T 4 Wire
1
TX+
2
TX-
3
RX+
6
RX-
Protection - Non-Standard 100Base-T 4 Wire
4
TX+
5
TX-
7
RX+
8
RX-
23.5.3
DC
The DC port is UL-60950 compliant, with a 2-pin connector.
Figure 358: IP-20C DC Port Connector
23.5.4
RSL Interface
IP-20C-HP uses a dual-pin connector.
Note:
The voltage at the RSL interface is 1.XX where XX is the RSL level. For
example: 1.59V means an RSL of -59 dBm. Note that the voltage
measured at the BNC port is not accurate and should be used only as
an aid).
23.5.5
Source Sharing
IP-20C-HP uses a TNC connector for source sharing. This connector is marked
EXT/REF.